66
5784 568 - 03
Vitodens 100-W, B1HA series & B1KA Combi Installation/Service
Technical Data
(continued)
Additional Information
Standard heating boiler
Boiler Model No.
B1HA 26
B1HA 35
B1KA 35
CSA input Natural gas (NG)
CSA input Liquid propane Gas (LPG)
CSA output/DOE
1
heating capacity NG
CSA output/DOE
1
heating capacity LPG
Net AHRI rating
2
MBH
kW
MBH
kW
MBH
kW
MBH
kW
MBH
21-94
6.2-27.5
31-94
9.1-27.5
20-87
5.7-25.6
29-87
8.4-25.6
76
21-125
6.2-36.6
31-125
9.1-36.6
20-116
5.7-34.1
29-116
8.4-34.1
101
21-125
6.2-36.6
31-125
9.1-36.6
20-116
5.7-34.1
29-116
8.4-34.1
101
Heat exchanger surface area
ft.
2
m
2
12.96
1.2
12.96
1.2
12.96
1.2
Min. gas supply pressure
Natural gas
LPG
“w.c.
“w.c.
4
10
4
10
4
10
Max. gas supply pressure
3
Natural gas and LPG
“w.c.
14
14
14
A.F.U.E.
%
95.0
95.0
95.0
Weight
lbs
kg
79.4
36
79.4
36
90.0
41
Shipping weight
lbs
kg
88.2
40
88.2
40
99.2
45
Boiler water content
USG
L
1.02
3.88
1.02
3.88
1.02
3.88
Boiler max. flow rate
4
GPM
L/h
6.2
1400
6.2
1400
6.2
1400
Max. operating pressure
(max. allowable working pressure)
at 210ºF (99ºC)
psig
bar
45
3
45
3
45
3
Boiler water temperature
- Adjustable high limit (AHL) range
- space heating (steady state)
- DHW production (set-point)
- Fixed high limit (FHL)
ºF (ºC)
ºF (ºC)
ºF (ºC)
86 to 176 (30 to 80)
176 (80)
210 (99)
Boiler connections
Boiler heating supply and return
Pressure relief valve
DHW tank heating supply/return
DHW heating
Drain valve
NPTM (male)
NPTF (female)
NPTM (male)
NPTM (male)
(male thread)
c
in.
c
in.
c
in.
--
c
in.
c
in.
c
in.
c
in.
--
c
in.
c
in.
c
in.
--
b
in.
c
in.
Dimensions
Overall depth
Overall width
Overall height
inches
(mm)
inches
(mm)
inches
(mm)
15
c
(400)
15
c
(400)
30
a
(768)
15
c
(400)
15
c
(400)
30
a
(768)
15
c
(400)
15
c
(400)
30
a
(768)
1
Output based on 140ºF (60ºC), 120ºF (49ºC) system supply / return temperature.
2
Net AHRI rating based on piping and pick-up allowance of 1.15.
3
If the gas supply pressure exceeds the maximum gas supply pressure value,
a separate gas pressure regulator must be installed upstream of the heating system.
4
See “System Flow Rates” on pages 25 and 26 in this manual.