Press the following keys:
1.
CD
simultaneously and
briefly (< 2 s); the display
shows "
SET
".
2.
CD
simultaneously and
briefly; the display shows
"
Coo
".
3.
CD
simultaneously and
briefly; the display shows
the current set value.
4.
C
to raise the set value
or
5.
D
to lower the set value
6.
CD
simultaneously and for at
least 5 s; the change is
saved and the next
higher menu level is dis-
played.
7.
To return to the standard display
(return temperature), repeat step 6
several times.
Standard setting
12 °C
Setting range
10 to 15 °C
Scanning sensor values
Press the following keys:
1.
CD
simultaneously and
briefly (< 2 s); the dis-
play shows "
SET
".
2.
D
to display "
tP
".
3.
CD
simultaneously and
briefly; the display
shows "
T01
".
4.
CD
simultaneously and
briefly; the display
shows the temperature
at the
return tempera-
ture sensor (ST1)
.
5.
CD
simultaneously and at
least for 5 s; the display
shows "
T01
".
6.
D
to display "
T02
".
7.
CD
simultaneously and
briefly; the display
shows the temperature
at the
flow tempera-
ture sensor (ST2)
.
8.
CD
simultaneously and at
least for 5 s; the display
shows "
T02
" again.
9.
D
to display "
T03
".
10.
CD
simultaneously and
briefly; the display
shows the temperature
at the
air heat exchan-
ger sensor (ST3)
.
Selecting the set value for cooling mode (Coo)
32
Control settings
5692
695
GB
Summary of Contents for OC208HM