Important Precautions

4

Safety

Take note of all symbols and notations intended to draw attention to potential hazards or important product information.
These include “DANGER,” “WARNING,” “CAUTION,” and “INFORMATION.” See page 2 for details.

Approvals

Viessmann boilers, burners and controls
are approved for sale in North America by
International Approval Services (IAS). All
electrical wiring is to be done in
accordance with the latest edition of the
National Electrical Code ANSI/NFPA 70.
In Canada use latest edition of CSA
C22.1 Part 1 and/or local codes.

Please carefully read this manual prior
to attempting installation. Any
warranty is null and void if these
instructions are not followed.
We offer frequent installation and
service seminars to familiarize our
partners with our products. Please
inquire.

Working on the equipment

The installation, adjustment, service, and
maintenance of this boiler must be done
by a

licensed professional heating

contractor

who is qualified and

experienced in the installation, service,
and maintenance of hot water heating
equipment. There are no user-serviceable
parts on this equipment.

Power supply

Install power supply in accordance with
the regulations of the authorities having
jurisdiction or, in the absence of such
requirements, in accordance with National
Codes.
Viessmann recommends the installation
of a disconnect switch to the 120 V power
supply outside of the boiler room. The
installer must provide maximum 15 A
overcurrent protection for the 120 V
power supply (fuse or circuit breaker).

Ensure that all contacts have sufficient
insulation clearance to live parts and
are certified for these applications.
Proper consultation with Viessmann
Manufacturing Company Inc. should
occur when installing components not
included in the Viessmann product
line.

No static discharge to the internal
componentry must ever occur when
working with opened control
equipment.

Important Installation Requirements

Literature applicable to installation of the
Dekamatik-HK 1:
- Installation Instructions
- Start-up and Service Instructions
- Operating Instructions

- Installation codes mentioned in this

manual

Leave all literature at the installation
site and advise the system
operator/ultimate owner where the
literature can be found. Contact
Viessmann for additional copies.

5167

137

IMPORTANT

Turn off electric
power supply before
servicing. Contact
with live electric
components can
cause shock or loss
of life.

WARNING

IMPORTANT

IMPORTANT

Summary of Contents for Dekamatik-HK1

Page 1: ...tallation Instructions Dekamatik HK1 Digital indoor outdoor heating circuit control unit for mounting on the mixing valve Part No 7450 107 for wall mounting Part No 7450 110 Please file in Service Bin...

Page 2: ...s H Advice to owner Once the installation work is complete the heating contractor must familiarize the system operator ultimate owner with all equipment as well as safety precautions requirements shut...

Page 3: ...on Dekamatik HK1 for Mounting on the Mixing Valve 8 Dekamatik HK1 for Wall Mounting 9 Electrical Connections Overview 10 Sensors 12 Supply temperature sensor 12 Outdoor temperature sensor 13 Accessori...

Page 4: ...nstall power supply in accordance with the regulations of the authorities having jurisdiction or in the absence of such requirements in accordance with National Codes Viessmann recommends the installa...

Page 5: ...igital indoor outdoor heating circuit control unit for one heating circuit with mixing valve either with drive module for mounting on Viessmann mixing valve or for wall mounting and connection of a se...

Page 6: ...iessmann 2 wire BUS for communication with other Dekamatik control units External heat demand external heat disable 1It is possible to connect a separate room temperature sensor accessory instead of t...

Page 7: ...Heating circuit pump Power supply Remote control 2 Viessmann 2 wire BUS for communication with other Dekamatik control units External heat demand external heat disable 1It is possible to connect a sep...

Page 8: ...ending on size of mixing valve onto the threaded bolts of the mixing valve 2 Place the base plate in position and screw on with the washers and nuts provided 3 Snap the control unit with drive module...

Page 9: ...the wall with three screws 3 Carry out the electrical connections i e mixing valve motor and compiled fault indication see page 18 and 19 4 Pull off the cover 5 Push the control unit in the guideways...

Page 10: ...ltage connections X14 for outdoor temperature sensor or room temperature sensor accessory supply temperature sensor X3 not used or X3 for return temperature sensor accessory in conjunction with underf...

Page 11: ...1 Overview continued Wall mounting fixture Terminal strips for connection of mixing valve motor or compiled fault indication 5167 137 Fig 4 Electrical connections in the wall mounting fixture Dekamati...

Page 12: ...right 2 Open the case of the sensor with a screwdriver 3 Place the perforated mounting strap supplied inside the sensor case on the tensioning screw run it around the supply pipe and place back on the...

Page 13: ...f the heating circuit controls the south facing part of the building the outdoor temperature sensor must be mounted on the south facing wall Ensure that the outdoor temperature sensor is not located o...

Page 14: ...elief clamp 4 Insert connector in socket X 14 in the terminal compartment see page 10 install strain relief clamp Wall mounting fixture for using the programming unit as a remote control The programmi...

Page 15: ...10 install strain relief clamp 8 Insert the programming unit in the wall mounting fixture WS remote control unit RS remote control unit Remote control unit 1 Mount the remote control unit in accordan...

Page 16: ...t the 3 wire cable from the heating circuit pump to connector 3 Insert connector in the socket for the heating circuit pump 5167 137 In the case of underfloor heating systems a high limit aquastat imm...

Page 17: ...wire according to the rating of the pump to be connected 3 Connect the heating circuit pump to the contactor 3 Phase pumps require use of contactors with overload protection 4 Connect contactor to con...

Page 18: ...reak open the cable bushing install strain relief clamp 3 Insert connector in socket X 11 in the terminal compartment see page 10 install strain relief clamp External heat demand or external changeove...

Page 19: ...oiler control unit a compiled fault message is also relayed to these via the Viessmann 2 wire BUS accessory Wall mounting fixture 1 Select the signal device provided by the customer Rated voltage AC 1...

Page 20: ...nce with the regulations of the authorities having jurisdiction or in the absence of such requirements in accordance with National Codes The Dekamatik HK 1 is standard equipped with a 120 V power cord...

Page 21: ...ng valve motor is properly connected j Ensure correct rotational direction of mixing valve motor and if necessary change in accordance with the Service Instructions j Ensure heating circuit pump is pr...

Page 22: ...s II Degree of protection IP 22 D to EN 60529 Ambient temperature during operation 32 to 104 F 0 to 40 C during storage and transport 4 to 104 F 20 to 65 C Dead zone of PI controller for mixing valve...

Page 23: ...Appendix 23 Notes 5167 137...

Page 24: ...iessmann ca mail viessmann ca Viessmann Manufacturing Company U S Inc 45 Access Road Warwick Rhode Island 02886 USA Tel 401 732 0667 Fax 401 732 0590 www viessmann us com mail viessmann us com 24 5167...

Reviews: