Electrical Connections
14
Accessories
Room temperature sensor
Room temperature sensor
Supply temperature sensor
1.
Mount the room temperature sensor in
accordance with the separate
installation instructions.
2.
Connect the 2-wire cable from the
room temperature sensor to
connector
at terminals “1” and “2”
(the wires are interchangeable).
3.
Break open the cable bushing; install
strain relief clamp.
4.
Insert connector
in socket “X 14”
in the terminal compartment (see
page 10); install strain relief clamp.
Wall mounting fixture (for using the programming unit as a remote control)
The programming unit of the control unit
can be used as a remote control in the
wall mounting fixture (accessory).
1.
Remove the cover
.
2.
Take the programming unit
out of
the control unit.
3.
Fit the blank cover of the wall
mounting fixture in the control unit.
5167
137
Fig. 11
Connecting the room temperature sensor to the Dekamatik-HK 1
Fig. 12
Taking the programming unit out of the control unit