3
Handling
3.1
Transport and storage
Observe the following with transport and storage:
n
Avoid heavy blows and vibrations.
n
Store components in a clean and dry place.
n
Do not remove the components from the packaging until immedi‐
ately before use.
3.2
Assembly information
3.2.1
Mounting conditions
Mounting the device is permissible only if the following conditions are
met:
n
The device must be mounted in potable water installations only.
n
In series pipelines, the flushing station must be arranged as the last
consumer.
n
In ring and series pipelines for hot potable water (PWH), comply with
the output times pursuant to the applicable regulations, see
ulations from section: Mounting conditions“ on page 6
n
Access to the flushing station must be possible for maintenance and
repair. All components of the flushing station must be easily acces‐
sible.
n
Installation below the backflow level is only permissible if the water is
drained by means of a wastewater pump station.
n
Only use DVGW approved sealants in accordance with the appli‐
„Regulations from section: Mounting condi‐
Handling
Flushing station with Viega technology
17