4. TRANSMITTED EVENTS LIST

The  XTO-iP panel can be configured to enable or disable the 

transmission of events like alarms or defaults.

The installer can modify the default sending settings for those 

events, although it will end the EN50131 standard compliance. 

How to modify the transmission state

 

• 

At initial programming,  right after the PERIODIC TEST CALL step: 

• 

After initial programming, using a remote keypad  : 

Example : 

If the monitoring station system is set to receive arms and disarms, the 

ARM / DISARM

 parameter must be 

changed from 

NOT TRANSMITTED

 to 

ALARM / END

.

Press 

OK or YES

 to access 

EVENT TRANS. MODIFICATION

 menu.

CODE/STATE 

MODIFICATION

Use the arrows       

             to access :

CONFIGURATION

  (level 4) >

 CONFIGURATION MONITOR. STATION 

MONITORING PARAMETERS

 > 

EVENT TRANS. MODIFICATION

Then use the arrows  

 

   to determine the event to modify. Press 

OK or YES

  to edit.

These are the default transmitted events  :

DEVICE 

(intrusions)  

ALERT 

(Panic Buttons)

PANEL LOW BATT.

TAMPER

DEVICE LOW BATT.

PERIODIC TEST

DURESS CODE

FIRE

MEDICAL ASSIST.

ETHERNET CABLE 

AC POWER LOSS 

(AC Power supply) 

The following events are not sent by default :

PANEL RESET

PHONELINE FAULT 

RADIO JAMMING

SUPERVISION

5 WRONG CODES

ALARM CANCEL

ARM/DISARM  

(On/Off)

ZONE BYPASS 

(bypass function enabling/dsiabling)

SWINGER SHUTDOWN

There is 3 different transmission states :

ALARM

 : event transmitted upon occurrence

ALARM/END : 

 event is transmitted on occurrence and on event restoral

NOT TRANSMITTED : 

event is not transmitted, however it will appear on the keypad. 

Summary of Contents for XTO-IP

Page 1: ...XTO IP ALARM PANEL INSTALLATION MANUAL DOC REF 230 XTO IP AUS MODIF DATE NOVEMBER 2016 FIRMWARE VERSION XLP 04 04 00 XXX AND LATER 1 ...

Page 2: ...signal integrity and optimal security The reliability of the signal is guaranteed thanks to the two way radio frequency transmissions with all the peripherals of the Videofied product line The integrated antennas allow the system to be totally wireless thus preventing from the system beeing inelegant and cumbersome and eliminating the installation problems The jamming detection feature identifies ...

Page 3: ...6 1 6 Cover locking 6 2 XTO iP panel programming 7 3 XTO iP features guide 13 3 1 Get to access level 4 13 3 2 How to Arm Disarm the system 13 3 3 Arming and Siren Mode Configuration 14 3 4 Manage badges and access codes 15 3 5 Delete the keypad or any other device 17 3 6 Read the event log 18 3 7 Golden rules 18 4 Transmitted events list 19 5 2G3G error codes 20 6 Technical specification and secu...

Page 4: ...e bracket the latter beeing used to attach the panel to the wall or a pole Mounting the panel is not required for programming Screwholes 1 1 SIM card installation Before removing the front cover from its box Put the SIM card on the plastic base Take care to respect the right direction DO NOT insert or remove the SIM card while the panel is powered ...

Page 5: ...LSH20 Lithium batteries Always replace all 4 batteries at once Mixing new and used batteries can severely damage the panel risk of explosion Press and hold the PROGRAMMING BUTTON for 10 seconds until the indicator LED blinks twice The panel is now reset a CMA XMA or XMB has to be enrolled to configure the panel Programmingbutton ...

Page 6: ...e of the following screens 1 4 Pairing the remote keypad RSI c 2013 YLGHR HG FRP XX or Press on both CLR and ESC NO keys at the same time and release The indicator LED on the keypad will blink rapidly Wait for the keypad to pair If the keypad doesn t pair up with the panel and shows XX it certainly means that it is still paired to another system and needs to be reset Take the batteries out and pre...

Page 7: ... This test measures the strength of communication between the device and the control panel The keypad will display a real time radio range value on a scale of 9 To receive the most accurate results you must run the radio range test for at least 30 seconds Result must be 8 out of 9 or better for reliable transmission Using the Alphanumeric Keypad enter the Installer Code of your choice The Installe...

Page 8: ...is used it cannot be set later the system must be defaulted Leaving the name blank by pressing ESC NO it will be named ACCESS 1 by default Please wait ADJUSTING DATE AND TIME DATE YEAR 12 To set the year OK orYES DATE MONTH 13 01 To set the month OK orYES You may proceed in the same way for Day Hour and Minutes 13 10 14 10 47 ENTRY COMPLETE ACCOUNT NUMBER CONNECTED TO 021 725 67 7 21 OK orYES Use ...

Page 9: ...ATION Keypad display Actions and comments The CODE STATE MODIF menu is to configure the transmitted events to the monitoring station use the arrow keys to toggle between events and OK or YES to modify ALARM event transmitted upon occurrence ALARM END event is transmitted on occurrence and on event restoral NOT TRANSMITTED event is not transmitted however it will appear on the keypad Please liaise w...

Page 10: ...he back up server and IP Domain name TMT and PORT TMT to configure remote maintenance server OK orYES ESC NO ESC NO OK orYES APN CODE LQWHUQHW HQWUHSU USER NAME RUDQJH PASSWORD RUDQJH The APN Code Access Point Name User Name and Password are supplied by the mobile operator Please make sure you have entered the code exactly as indicated by your local SIM card operator Press OK orYES to enter modify ...

Page 11: ...rors codes and contact your technical support If the screens shuts down press any key to light it up except OK orYES ESC NOou CLR The 2G3G level test can last several minutes Do not interrupt the test or remove the SIM card during the test IMPORTANT Videofied will require a 3 5 grade or better for reliable transmission of Video alarms For full compatibility with EN50131 press OK orYES Otherwise pre...

Page 12: ...O After initial programming has been completed the system cannot be armed or disarmed until a user code or badge is entered the installer code cannot arm or disarm the system Press OK or YES to register one or more badges ESC NO if you re not using any badges If you wish to use an user code please skip this step and when initial programming is completed go to the BADGES ACCESS CODES menu please re...

Page 13: ...ur user code and press OK orYES Press press OK orYES and enter your user code With remote badge reader BR N A Present your badge on the badge reader N A N A With remote keyfob N A N A Press Press 3 1 Get to Access level 4 Tue 29 10 11 23 DISARMED LVL 1 ACCESS LEVEL 1 ACCESS LEVEL LEVEL 1 ACCESS LEVEL LEVEL 4 OK orYES OK orYES To unlock and get access to the installer level 4 you need to successive...

Page 14: ...in effect for this special profile Select the siren mode using the direction arrows then press OK YES A Armed D Disarmed P Perimeter bydefault allopeningcontacts E External bydefault allopeningcontacts withexternalaccess You can set your devices as External Perimeter ou External Perimeter Please go to the menu CONFIGURATION LVL 4 AREAS AND DEVICES DEVICES DEVICES CONFIGURATION DEVICE TYPE Siren Imme...

Page 15: ...og test the devices Modifications of the settings are not possible at this level User Level 3 can create Level 2 or Level 3 access codes or badges LVL 4 INSTALLER level where it is possible to modify the setup of the panel To access Level 4 the approval of a Level 3 oe Level 2 user is required Installer Level 4 can create the first Level 3 access code only How to return to the LVL1 After 1 min of no...

Page 16: ... code is created 1000 for example the 2 next codes and previous codes 0998 0999 1001 and 1002 will be automatically reserved The 1 code 1001 is used for disarming under duress The 2 code 1002 is used for panic The 1 and 2 codes 0998 et 0999 are reserved to prevent conflicts when creating a new user code Reserved Codes 000000 From 9998 to 9999 From 99998 to 99999 From 999898 to 999999 From 314157 to...

Page 17: ...device You can now remove the batteries from the device ACCESS LEVEL 4 CONFIGURATION GENERAL PARAMETERS OK orYES to select the device and press OK orYES XX DELETE AREAS AND DEVICES DEVICES ADD A NEW DEVICE DEVICE CONFIGURATION A1 KEYPAD KEYPAD 1 OK orYES OK orYES OK orYES HYLFHV OLVW OK orYES OK orYES ...

Page 18: ... on the lens 9 10 To switch between UPPER and lower case use the M m key from the CMA keypad or hold a digit key 0 to 9 for XMA XMB 11 Internalcomponentsarefragile becarefulopeningor closing the panel LCD screen goes dark after 30 seconds of inactivity press an arrow or numeric key to light it up 13 Use onlybatteries providedbyVideofied siren Alkaline batteries 14 Infrareddetectorsshouldneverbeinst...

Page 19: ...E STATE MODIFICATION Use the arrows to access CONFIGURATION level4 CONFIGURATIONMONITOR STATION MONITORINGPARAMETERS EVENTTRANS MODIFICATION Then use the arrows to determine the event to modify Press OK orYES to edit These are the default transmitted events DEVICE intrusions ALERT Panic Buttons PANEL LOW BATT TAMPER DEVICE LOW BATT PERIODIC TEST DURESS CODE FIRE MEDICAL ASSIST ETHERNET CABLE AC PO...

Page 20: ...codes are subject to change by SIM card operators However the GPRS level test errors results in the majority of cases have the following causes SIM Card activation Delay Some operators require an additional delay up to 48 hours to activate automatic data transmission Please check with your operator prior to installation APN CODE USERNAME and PASSWORD The GPRS 2G3G settings are supplied by the oper...

Page 21: ... delay Infinite BOX Physical and Environmental Data Operating temperature 25 70 C Maximum relative humidity 95 sans condensation International Protection Marking IP54 IK06 Material ABS ULV0 Dimensions Panel 272 mm x 276 mm x 96mm Installation Mounting Control panel Base 4 screws to close the cover 4 screws on panel base for brackets mounting STANDARDS CERTIFICATIONS XTO iP730 Australia A Tick AS NZ...

Reviews: