8. Technical Data
MultiPlus 12/2000/80
MultiPlus 24/2000/50
MultiPlus 48/2000/25
PowerControl / PowerAssist
Yes
Transfer switch
50A
INVERTER
Input voltage range
9,5 – 17V
19 – 33V
38– 66V
Output
Output voltage: 120VAC ± 2%
Frequency: 60Hz ± 0,1% (1)
Cont. output power at 25°C (3)
2000VA
Cont. output power at 25°C
1600W
Cont. output power at 40°C
1400W
Cont. output power at 65°C
1000W
Peak power
3500W
Maximum efficiency in %
93 / 94 / 95
Zero-load power
10 / 11 / 11W
Zero-load power search mode
3 / 4 / 4W
CHARGER
AC Input
Input voltage range: 95-140 VAC
Input frequency: 45 – 65 Hz
Charge voltage 'absorption'
14,4 / 28,8 / 57,6V
Charge voltage 'float'
13,8 / 27,6 / 55,2V
Storage mode
13,2 / 26,4 /52,8V
Charge current house battery (4)
80 / 50 / 25A
Charge current starter battery
1 A (12V and 24V models only)
Battery temperature sensor
Yes
GENERAL
Programmable relay (5)
Yes
Protection (2)
a – g
Common Characteristics
Operating temp. range: -40 to +65°C (fan assisted cooling)
Humidity (non-condensing): max 95%
ENCLOSURE
Common Characteristics
Material & Colour: Steel/ABS (blue RAL 5012) Protection category: IP 21
Battery-connection
M8 bolts
230V AC-connection
Screw terminals 13 mm² (6 AWG)
Weight
15,2kg
Dimensions (h x w x d)
506 x 234 x 146 mm
STANDARDS
Safety
EN-IEC 60335-1, EN-IEC 60335-2-29, EN 62109-1
Emission / Immunity
EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3
IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
Road vehicles
ECE R10-4
MultiPlus 2kVA 120V
Page 17
Technical Data