5.2.2 Connecting 2 or more Multis or Quattros
If 2 or more Multis or Quattros are connected to the Lynx Ion BMS then an additional relay needs to be installed to extend the
Allow-to-charge and Allow-to-discharge contacts.
Example: 2 Multis
The Allow-to-charge and Allow-to-discharge will be extended by a relay with 2 separate contacts to control two Multis or
Quattros.
Schematic view of the relay that can be used:
NOTE: It is also possible to use separate relays to get the required additional contacts.
Below a schematic view of the setup:
In this schematic relay K3 is the Allow-to-charge and K4 the Allow-to-discharge. The letters ‘B’ and ‘C’ are the different contacts
within that specific relay.