173
MAINTENANCE
Maintenance
Reverse Idler Port
Lubricate the reverse idler shaft and gear at every oil change (except the 500 mile/800 km
break-in service). Refer to the Periodic Maintenance Table. We recommend the use of
VICTORY Multi-Purpose Lubricant (P/N 2872863).
1. Stop the engine and position the motorcycle on
its sidestand.
2. Remove the idler port screw from the reverse
gear cover.
3. Spray the lubricant into the port hole for 2-3
seconds.
4. Raise and lower the reverse gear lever to clean
the shaft and distribute the lubricant. Repeat if
necessary. Make sure lever action is smooth
and non-binding.
5. Reinstall the port screw and torque to 50 lb-in.
(5.6 Nm).
Idler Port Screw
visionownersmanual.book Page 173 Wednesday, February 13, 2008 4:31 PM