AUTO-CUT 200 XT
Manual 0-5253
INSTALLATION
3-1
SECTION 3: INSTALLATION
3.01 Installation Requirements
Electric Supply
The electrical supply network, the gas and water supply system must meet local safety standards. This
conformity must be checked by qualified personnel.
Auto-Cut 200 XT™Power Supply
Input
Power Input
Current
Suggested Sizes (See Note)
Voltage
Freq.
3-Ph
3-Ph
Fuse (Amps)
Wire (AWG)
Wire (mm
2
)
(Volts)
(Hz)
(kVA)
(Amps)
3-Ph
3-Ph
3-Ph
380
50/60
41
63
100
#6
16
* Suggested wire size based on United States NFPA 70 National Electrical Code 2011
edition published by the National Fire Prevention Association. Listings are from table
400.5(A)(2) for flexible cord of certain types rated for 75 deg C in ambient tempera-
tures up to 30 deg C. Using wires of lower temperature rating or different insulation
type may require larger wire size. Derate for higher ambient.
These are suggestions only. Always refer to your local and national codes that apply to
your region for final determination of correct wire type and size.
CAUTION
Fuse and wire sizes are for reference only. The installation must conform to national and local codes for the type
and method of wire being used.
Gas Supply
The customer must supply all gas and pressure regulators. Gases must be of high quality. Pressure regula
-
tors must be double-stage and installed as close as possible to the gas console. Contaminated gas can cause
one or more of the following problems:
• Reduced cutting speed
• Poor cut quality
• Poor cutting precision
• Reduced consumables life.
• Oil or grease contamination from compressed or bottled air can cause fires in conjunction with oxygen.
Cooling System Requirements
Coolant must be added to the system on installation. The amount required varies with torch leads length.
Thermal Dynamics recommends the use of its coolants 7-3580 and 7-3581 (for low temperatures).
Coolant Capabilities
Cat. Number and Mixture
Mixture
Protects To
7-3580 ‘Extra-Cool
TM
’
25 / 75
10° F / -12° C
7-3581 ‘Ultra-Cool
TM
’
50 / 50
27° F / -33° C
7-3582 ‘Extreme Cool
TM
’
Concentrate*
-65° F / -51° C
* For mixing with D-I Cool
TM
7-3583
Summary of Contents for Auto-Cut 200 XT
Page 4: ...This page intentionally blank...
Page 8: ...TABLE OF CONTENTS...
Page 48: ...AUTO CUT 200 XT INSTALLATION Manual 0 5253 This Page Intentionally Blank...
Page 66: ...This Page Intentionally Blank...
Page 97: ...AUTO CUT 200 XT Manual 0 5253 APPENDIX A 11 This Page Intentionally Blank...
Page 107: ...AUTO CUT 200 XT Manual 0 5253 APPENDIX A 21 Display PCB Test Points TP1 GND TP2 5VDC TP3 24VDC...
Page 116: ...AUTO CUT 200 XT APPENDIX Manual 0 5253 APPENDIX 12 CAP BIAS BOTTOM PCB LAYOUT Art A 11685...
Page 117: ...AUTO CUT 200 XT Manual 0 5253 APPENDIX A 31 APPENDIX 13 CAP BIAS TOP PCB LAYOUT Art A 11686...
Page 118: ...AUTO CUT 200 XT APPENDIX Manual 0 5253 APPENDIX 14 SUPPRESSOR PCB LAYOUT Art A 11684...
Page 121: ...AUTO CUT 200 XT Manual 0 5253 APPENDIX A 35 This Page Intentionally Blank...
Page 163: ...AUTO CUT 200 XT Manual 0 5253 APPENDIX A 77 This Page Intentionally Blank...
Page 165: ......