TROUBLESHOOTING (CONTINUED)
PROBLEM
POSSIBLE CAUSE
SOLUTION
Pipe will not fit into tool.
Grooving head is not set to home position.
Reset grooving head to home position. Refer to the
“Troubleshooting” section.
Pipe stops rotating during
grooving.
Pipe is slipping in the power drive chuck.
Securely tighten the power drive chuck.
The circuit breaker/GFI has tripped or a fuse
has blown out on the electrical circuit that
supplies the power drive.
Test/reset the jobsite GFI/breaker, or replace the fuse. Upon
restoration of power, cut off pipe end and re-groove.
Facility has lost power.
Upon restoration of facility power, cut off pipe end and re-groove.
Tool stalls mid-cycle, or will
not groove after actuating.
Tool has reached end of life.
Replace tool.
Tool will not groove pipe.
Tool is not fully pushed onto the pipe.
Push the tool all the way onto the pipe.
Pipe does not extend far enough out of
the chuck.
Rechuck pipe so that the end to be grooved extends a minimum of
2 inches past the edge of the chuck.
Pipe is rotating clockwise.
Reverse power drive direction to create counterclockwise rotation
of the pipe.
In the event of tool malfunction outside the scope of the troubleshooting section, contact Victaulic for
assistance.
20