DRIVE SETUP
1.
Plug the power drive cord into the provided
safety foot switch, as shown above . Refer to the
power drive manufacturer’s operating manual for
additional information .
2.
Place the safety foot switch on the same
side of the tool as the power drive switch, with
adequate clearance for ease of use and to avoid
a tripping hazard .
WARNING
• The power drive must be operated with
a safety foot switch. If the power drive
is not supplied with a safety foot switch,
contact Victaulic.
Operating the tool without a safety foot
switch could result in serious personal
injury.
3.
Turn the switch on the side of the power drive
to create counterclockwise rotation (as seen
from the front power drive chuck) .
Dir
ect
ion of
Rotation
4.
Depress the safety foot switch . Verify that the
pipe rotates counterclockwise when viewed from
the front power drive chuck . Remove foot from
the safety foot switch .
If the pipe rotates clockwise when viewed
from the front power drive chuck, return to
the previous step and verify the direction of
the power drive . Do NOT groove with the pipe
rotating clockwise .
11
REV_C
TM-RG2910
/ Operating and Maintenance Instructions Manual
Summary of Contents for RG2910