UG:121
Page 18
Specifications (Cont.)
Typical at 25°C, nominal line and 75% load, unless otherwise specified.
[a]
Do Not to exceed an input current of 7.5A
[b]
See Vicor module specifications. A preload may be necessary for modules trimmed down below 90% of normal
output voltage.
[c]
For special and adjustable voltages, maximum setpoint accuracy is 2% of V
NOM
.
[d]
131% nominal for booster modules. No OVP for VI-J00.
[e]
VI-J00 modules only.
[f]
For special, adjustable voltages and 48V
DC
outputs, maximum set-point accuracy is 2% of V
NOM
.
Note:
See individual module data sheets for specific module specifications.
[g]
Micro modules do not support remote sense.
[h]
Opening, repairing or modifying the unit will void the warranty. If you have any problem with the power supply,
please contact Customer Service at 1-800-735-6200. If the unit needs to be returned for inspection/analysis, an
RMA number will be issued. All units must have a RMA number prior to return.
Environmental
Storage Temperature
–40 to +85°C
Operating Temperature
Full Power
Half Power
–20 to +45°C (–40 to +45°C option w/MI chassis)
–20 to +65°C (–40 to +60°C option w/MI chassis)
Altitude
Derate 2.6% total output power for each 1,000ft to a maximum operating
altitude of 15,000ft. Non-operating storage maximum altitude is 40K.
Shock and Vibration
Mil-STD 810 (MI rugged chassis only)
Humidity
0 – 95% non condensing
Product Weight
5.2lbs [2,4kg]
Dimensions
1.86 x 5.06 x 10.40in [47,3 x 128,5 x 264,1mm]
Warranty
[h]
2 years limited warranty.
See