UG:121
Page 17
Specifications (Cont.)
Typical at 25°C, nominal line and 75% load, unless otherwise specified.
[a]
Do Not to exceed an input current of 7.5A.
[b]
See Vicor module specifications. A preload may be necessary for modules trimmed down below 90% of normal
output voltage.
[c]
For special and adjustable voltages, maximum set-point accuracy is 2% of V
NOM
.
[d]
131% nominal for booster modules. No OVP for VI-J00.
[e]
VI-J00 modules only.
[f]
For special, adjustable voltages and 48V
DC
outputs, maximum set-point accuracy is 2% of V
NOM
.
Note:
See individual module data sheets for specific module specifications.
[g]
Micro modules do not support remote sense.
Output (VI-200™/VI-J00™ Modules)
Parameter
Min
Typ
Max
Units
Notes
Set-Point Accuracy
[c]
0.5
1
%
of V
NOM
Load/Line Regulation
0.05
0.5
%
LL to HL,
10% to Full Load
Load/Line Regulation
0.2
0.5
%
LL to HL,
No Load to 10%
Temperature Regulation
0.01
0.02
%/°C
Over rated temperature
Long-Term Drift
0.02
%/K hours
Output Ripple & Noise:
≤10V
OUT
>10V
OUT
100
1.0
mV
% V
OUT
20MHz bandwidth
Voltage Trim Range:
VI-200/VI-J00 Slots
50 – 110
% V
OUT
±10% on
10 – 15V
OUT
Total Remote-Sense
Compensation
0.5
Volts
Autosense.
See pages 6 & 14
OVP Set Point
[d]
115
125
135
%V
OUT
Recycle Power
Current Limit
105
115
125
% of I
MAX
Auto Recovery
Short Circuit Current
120 (105
[e]
)
130
%
Overtemperature Limiting
Not available on VI-J00
Maxi, Mini and Micro Series Modules
Parameter
Min
Typ
Max
Units
Notes
Set-Point Accuracy
[f]
±0.5
±1
% of V
NOM
Load/Line Regulation
±0.08
±0.45 (±7)
% of V
NOM
0 – 100%
Temperature Regulation
0.002
0.005
%/°C
–40 to 100°C
Long-Term Drift
0.02
%/K hours
Output Ripple and Noise:
≤10V
OUT
>10V
OUT
100
1.0
mV
%V
OUT
20MHz
bandwidth
Voltage Trim Range:
Maxi/Mini/Micro Slots
10 – 110
% V
OUT
Preload may be
required
Total Remote-Sense
Compensation
0.5
Volts
Autosense.
See pages 6 & 14
[g]
OVP Set Point
112
135
% of V
OUT
Recycle power
Current Limit
102
115
135
% of I
MAX
Auto Recovery
Overtemperature Limiting
Not available