43
–
ID:
Identification number generated in the order of creation,
Include
1-8,
Exclude
9-16.
–
Name:
User definable zone name.
–
Type:
Shows zone type and cannot be changed.
–
Threshold:
Determines the amount of change in the zone that will trigger event
(percentage, 1-100); a lower number increases alarm frequency.
–
Sensitivity:
User can change sensitivity of this function, where large value sets more
sensitive detection.
–
Dwell time:
Set the time an event lasts from the point of detection of a motion (hold
time).
–
Show Histogram:
This camera provides live histogram for easy setup of threshold
level in motion window. The pop-up window shows activity strength and threshold
level, and user can determine threshold level for triggering motion event by slide bar or
type in number.
User can select any box by clicking name on the preview window or on the list. User can delete
selected zone via right mouse click selection for a selected box or clicking the
X
button in the zone
list.
When the settings are complete, click
Save
button to save the settings, or click
Reset
button to clear
all of the information you entered without saving it.
Summary of Contents for V8360W Series