background image

UPPER HOUSING

CEILING TILE OR

 CEILING PANEL

ALIGNS AND 

TO STANDOFFS WHEN

USED WITH 

Figure 1
 Upper Housing

2.2 Wiring

Be sure that the area directly above the selected location
is clear of obstacles (such as steel beams, headers, pipes,
electrical wiring, etc.) which would interfere with the
mounting of the Omniscan.

All cabling enters the upper housing through a split plate
located on top of the housing. Cable routing is performed

during the installation steps described in Section 2.2
below; it is presented at this point for the convenience
of the installer. Grommets are provided to prevent cable
chafing. Multiple knockouts are also provided on the
side of the upper housing for wiring. Use conduit or
liquid tight fittings when using these knockout holes.
Refer to Figure 1.

2.3 Housing Installation

Three mounting configurations are possible with the

 (1) supported by an existing ceiling tile cut for

the Omniscan; (2) supported by a 

 ceiling panel

option; (3) supported by a 

 mounting rail kit.

1 .

2.3.1 Installation with Existing Tile

CAUTION: 

The ceiling tile used in this procedure

A

must be strong enough to support the combined
weight of the 

 and the camera/lens assembly.

Although the 

 is not heavy [upper housing

 have a combined weight 

of 

6.9 lb (3.1 kg);

refer to appropriate product specifications for the
weightsofthe cameraandlens], manytypesofceiling
tile have little tensile strength, so special care must
be taken if this installation method is used.

2.

3.

4.

Remove the tile in which the unit is to be mounted.

Using the 

 as a template, cut a circular

opening in the center of a ceiling tile. Test the fit of

the Omniscan and tile before proceeding with the

next step. The circular flange around the upper
housing rests on top of the tile and supports the

weight of the unit. Refer to Figure 1.

Lift the upper housing of the 

 into the ceiling

area and rest it on one of the tiles adjacent to the
opening it is going to occupy. Route the cables

through the split plate into the housing as described
in Section 2.2.

Install the tile prepared in Step 1 in the ceiling grid,

making sure it is seated properly.

Reach through the circular opening and move the

upper housing into place in the tile. Install the

camera as described in Section 2.4.

3

Summary of Contents for V7FCD

Page 1: ...on All Vicon equipment is tested and inspected before leaving the factory It is the carrier s responsibility to deliver the equipment in the same condition as it left the factory 2 1 1 INSPECTION FOR VISIBLE DAMAGE Immediately inspect the cartons upon delivery Make a note of any visible damage on all copies of the carrier s freight bill 2 1 2 INSPECTION FOR CONCEALED DAMAGE As soon as possible aft...

Page 2: ...ding type plug 12 Power Cord Protection Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them payin convenience receptacles an 8 particular attention to cords at plugs product the pointwhere theyexitfrom thevideo 13 0utdoorCableCrounding Ifanoutsidecablesystem isconnected to the video product be sure the cable system is grou...

Page 3: ...ith Existing Tile CAUTION The ceiling tile used in this procedure A must be strong enough to support the combined weight of the V7FCD and the camera lens assembly Although the V7FCD is not heavy upper housing anddome have a combined weight of 6 9 lb 3 1 kg refer to appropriate product specifications for the weightsofthe cameraandlens manytypesofceiling tile have little tensile strength so special ...

Page 4: ...ws provided Screws should be inserted downwards from the ceiling 2 3 3 Installation Using the V3380MR Mounting Rail Kit The V3380MR mounting rail kit may be used in con junction with either an existing ceiling tile or the V7FCP ceiling panel option If an existing ceiling tile is to be used cut a circular opening in the tile as described in Section 2 3 1 and set the tile aside 1 2 3 Find four 4 sup...

Page 5: ...crews and washers Loosen the nuts on the clips on the underside of the trim ring and slip the dome flange into the clips Refer to Figure 3 Attach the dome to the trim ring by tightening the nuts Verify that the lens clears the dome by l 4 inch 0 64 cm 6 Rotate the lower dome until the scene as viewed on the monitor is completely visible through the tinted viewing strip of the dome Reinstall the tr...

Page 6: ...o prevent removal of paint Again after waxing re move dust or lint with clean dry air CAUTION A Excessive pressure or rubbing on the dome s surface can cause permanent scratches that may render the dome unusable 6 Cleaning of the outer surface is accomplished with any nonabrasive cleaning cloth and cleaning agent that is safe for use on acrylic plastic Either liquid or spray cleaner wax suitable f...

Page 7: ...a Name and address of the company return ing the unit b Name of the Vicon employee who issued the R A C R A number d Brief description of the installation e Complete description of the problem and circumstances under which it occurs For service or returns from countries in Europe contact f Unit s original date of purchase if still under Warranty VICON INDUSTRIES U K LTD 3 Pack the unit carefully U...

Reviews: