The pre-wired heating element should be positioned 
between the 2 dissipators before attachment to 
ensure contact and hence guarantee correct heat 
diffusion.

Fig. 04 

Pass the heating wire under the fixing slide of the 
camera. Insert the 2-pin connector at the end of the 
cable into the correspondent support circuit socket, 
identified by J3 HEATER.
Reposition the internal support slide and close the 
housing.

6.1.6  Camera power supply installation

 

h

Not usable in housings with wiper device 
installed.

This chapter describes how to install the camera 
power supply option into the housing. There are 
2 types of camera power supply depending on 
requirements.
One model has an input voltage from 100-240Vac 
with an output voltage of 12Vdc, 1A.
The other has an input voltage of 230Vac and an 
output voltage of 24Vac, 400mA.

Fig. 05 

IN 100-240Vac - OUT 12Vdc.

Fig. 06 

IN 230Vac - OUT 24Vac.

Open the housing as described before.

6.1.4  Board and connection

 

h

Connect the safety earth to the relative 
terminal of the J1 connector.

BOARD DESCRIPTION

J1

Input power supply terminal: 100-240Vac or 
24Vac, 12Vdc

J2

Output power supply terminal (same voltage 
coming from J1)

J3

Output terminal for heating 

J4

Anti-opening switch terminal (optional)

J5

Camera power supply output terminal *

J7

Connector for power supply **

J8

Connector for fan

Tab. 01  * The camera output voltage can be 12Vdc or 24Vac 

in relation to the type of power supply installed (

"6.1.5 

Heater installation", page 6

). In case of jumper 

installation (only 12Vdc or 24Vac versions) the J5 
terminal presents the same voltage applied at input J1. 
** Refer t

"6.1.5 Heater installation", page 6

 to install 

a 12Vdc or 24Vac power supply.

J2 - OUT

J1 - IN

J5 - Camera

OUT

J8 - Blower

J3 - Heater

J7 - Power supply

SW1 - Power supply

J2 - Terminal

Fig. 03 

6.1.5  Heater installation

This section describes how to install the heater option 
in the housings not provided with. Heaters can be 
supplied with working voltages of 12Vdc/24Vac 
or 115/230Vac and include the pre-wired heating 
element suitable for the working voltage, metal 
dissipators and kit fastening screws.
Open the housing as described before. Fix the heater 
kit to the prearranged points on the body of the 
housing.

Summary of Contents for HOV

Page 1: ...HOV Side opening aluminium housing ...

Page 2: ......

Page 3: ...HOV Side opening aluminium housing ...

Page 4: ... 6 1 1 How to open the housing 5 6 1 2 Camera installation 5 6 1 3 Connection to the power supply line 5 6 1 3 1 Type of cable 5 6 1 4 Board and connection 6 6 1 5 Heater installation 6 6 1 6 Camera power supply installation 6 6 1 7 Blower installation 7 6 1 7 1 100 240Vac power supply 8 6 1 7 2 12Vdc or 24Vac power supply 8 6 1 8 Cooling device 8 6 1 9 Wiper system 9 6 1 10 Closing the housing 9 ...

Page 5: ...e same thing can be said for any person or company involved in the creation and production of this manual The device must be installed only and exclusively by qualified technical personnel Before any technical work on the appliance disconnect the power supply Do not use power supply cables that seem worn or old Never under any circumstances make any changes or connections that are not shown in thi...

Page 6: ...n Innovative and stylish housing designed to simplify installation and servicing HOV ensures total protection against all environmental conditions Due to its side opening the accessibility to the camera lens and all its connections is made far easier Its weatherproof features are ensured by neoprene rubber gaskets and 3 cable glands with their specific gaskets or by the sealing gaskets when instal...

Page 7: ... at least 10mm longer than the others The power supply cable conductors must be tied up next to the terminal Make sure the signalling and power supply cables are separated from each other 6 1 3 1 Type of cable The cable used for the connection to the power supply line must be suitable for the intended use Comply with the current national standards on electrical installations 6 Installing and assem...

Page 8: ...he relative terminal of the J1 connector Board description J1 Input power supply terminal 100 240Vac or 24Vac 12Vdc J2 Output power supply terminal same voltage coming from J1 J3 Output terminal for heating J4 Anti opening switch terminal optional J5 Camera power supply output terminal J7 Connector for power supply J8 Connector for fan Tab 01 The camera output voltage can be 12Vdc or 24Vac in rela...

Page 9: ...inside the body of the housing using the corner bracket and supplied screws Blow direction Fig 09 Using the screws supplied with the kit assemble the power supply with the support bracket 01 and the corner attachment bracket 02 using the points provided for this 01 02 Fig 07 Insert the 6 pin connector at the end of the cable into the correspondent one on the support circuit identified by J7 Fig 03...

Page 10: ...ltage and the correct power supply kit must be chosen 6 1 7 1 100 240Vac power supply Insert the 2 pin connector at the end of the cable into the corresponding one indicated by J8 FAN on the support circuit Fig 03 page 6 Install the camera power supply supplied with the blower kit as described in the chapter 6 1 6 Camera power supply installation page 6 Close the housing 6 1 7 2 12Vdc or 24Vac pow...

Page 11: ...e European Union there are separate collection systems for used electrical and electronic products 6 1 9 Wiper system This section describes how to connect housings fitted with wiper systems For these versions it is not necessary to install any component on the inside because they are supplied complete with everything that is needed depending on the model ordered Open the housing as described prev...

Page 12: ...55 EN60529 with bracket with internal cable channel IP44 EN60529 for models with cooling blower and double filter 10 Technical specifications 10 1 General Aluminium construction Sunshield in ABS Epoxypolyester powder painting RAL9002 colour Stainless steel external screws Supplied with instruction manual desiccant bag accessories for camera and lens mounting 10 2 Mechanical Cable glands 3xM16 Glas...

Page 13: ...nual 11 11 Technical drawings j jThe values are in millimeters 76 98 27 131 160 213 70 40 188 113 60 88 88 400 225 13 39 39 62 140 53 514 176 100 70 250 70 A A B B A A B B 9 0 R100 400 430 412 USABLE AREA USABLE AREA Fig 14 HOV ...

Page 14: ...dquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Vicon Germany Kornstieg 3 D 24537 Neumuenster Phone 49 0 4321 8790 Fax 49 0 4321 879 97 Far East Office Unit 5 17 F Metropole Square 2 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon security com ...

Reviews: