7  Instructions for normal 
operation

 

h

Do not use the wiper when the outside 
temperature is below 0°C or in case of ice.

8  Maintaining and cleaning

8.1  Window and plastic cover 
cleaning (PC)

We suggest to use neutral soap diluted with water 
or specific products for lens cleaning applied with a 
soft cloth.

 

h

Avoid ethyl alcohol, solvents, hydrogenated 
hydrocarbide, strong acid and alkali. Such 
products may irreparably damage the 
surface.

9  Disposal of waste 
materials

 

n

This symbol mark and recycle system 
are applied only to EU countries and not 
applied to the countries in the other area of 
the world.

Your product is designed and manufactured with 
high quality materials and components which can be 
recycled and reused.
This symbol means that electrical and electronic 
equipment, at their end-of-life, should be disposed of 
separately from your household waste.
Please dispose of this equipment at your local 
Community waste collection or Recycling centre.
In the European Union there are separate collection 
systems for used electrical and electronic products.

6.1.9  Wiper system

This section describes how to connect housings fitted 
with wiper systems.
For these versions it is not necessary to install any 
component on the inside because they are supplied 
complete with everything that is needed, depending 
on the model ordered.
Open the housing as described previously and 
identify terminal J1 on the circuit.

Fig. 12 

Connect terminal S, on terminal J1, to the main 
supply voltage phase.

P

S

C

J1 Terminal

Fig. 13 

Connect terminal C, on terminal J1, to the main 
supply voltage neutral.
Connect terminal P, on terminal J1, to a button that, 
when connected in turn to the main supply voltage 
phase, will start the wiper system when pressed. 
When the button is released the wiper blade will 
return to the rest position.
If you have a receiver with the Wiper control function, 
connect the SW, PER and COM terminals respectively 
to terminals S, P and C on terminal J1.

6.1.10  Closing the housing

Take the dessicant salt bag out of its trasparent pack 
and insert it into the housing. Then close the housing as 
soon as possible to maintain the dessicant capability of 
the salt bag.

Summary of Contents for HOV

Page 1: ...HOV Side opening aluminium housing ...

Page 2: ......

Page 3: ...HOV Side opening aluminium housing ...

Page 4: ... 6 1 1 How to open the housing 5 6 1 2 Camera installation 5 6 1 3 Connection to the power supply line 5 6 1 3 1 Type of cable 5 6 1 4 Board and connection 6 6 1 5 Heater installation 6 6 1 6 Camera power supply installation 6 6 1 7 Blower installation 7 6 1 7 1 100 240Vac power supply 8 6 1 7 2 12Vdc or 24Vac power supply 8 6 1 8 Cooling device 8 6 1 9 Wiper system 9 6 1 10 Closing the housing 9 ...

Page 5: ...e same thing can be said for any person or company involved in the creation and production of this manual The device must be installed only and exclusively by qualified technical personnel Before any technical work on the appliance disconnect the power supply Do not use power supply cables that seem worn or old Never under any circumstances make any changes or connections that are not shown in thi...

Page 6: ...n Innovative and stylish housing designed to simplify installation and servicing HOV ensures total protection against all environmental conditions Due to its side opening the accessibility to the camera lens and all its connections is made far easier Its weatherproof features are ensured by neoprene rubber gaskets and 3 cable glands with their specific gaskets or by the sealing gaskets when instal...

Page 7: ... at least 10mm longer than the others The power supply cable conductors must be tied up next to the terminal Make sure the signalling and power supply cables are separated from each other 6 1 3 1 Type of cable The cable used for the connection to the power supply line must be suitable for the intended use Comply with the current national standards on electrical installations 6 Installing and assem...

Page 8: ...he relative terminal of the J1 connector Board description J1 Input power supply terminal 100 240Vac or 24Vac 12Vdc J2 Output power supply terminal same voltage coming from J1 J3 Output terminal for heating J4 Anti opening switch terminal optional J5 Camera power supply output terminal J7 Connector for power supply J8 Connector for fan Tab 01 The camera output voltage can be 12Vdc or 24Vac in rela...

Page 9: ...inside the body of the housing using the corner bracket and supplied screws Blow direction Fig 09 Using the screws supplied with the kit assemble the power supply with the support bracket 01 and the corner attachment bracket 02 using the points provided for this 01 02 Fig 07 Insert the 6 pin connector at the end of the cable into the correspondent one on the support circuit identified by J7 Fig 03...

Page 10: ...ltage and the correct power supply kit must be chosen 6 1 7 1 100 240Vac power supply Insert the 2 pin connector at the end of the cable into the corresponding one indicated by J8 FAN on the support circuit Fig 03 page 6 Install the camera power supply supplied with the blower kit as described in the chapter 6 1 6 Camera power supply installation page 6 Close the housing 6 1 7 2 12Vdc or 24Vac pow...

Page 11: ...e European Union there are separate collection systems for used electrical and electronic products 6 1 9 Wiper system This section describes how to connect housings fitted with wiper systems For these versions it is not necessary to install any component on the inside because they are supplied complete with everything that is needed depending on the model ordered Open the housing as described prev...

Page 12: ...55 EN60529 with bracket with internal cable channel IP44 EN60529 for models with cooling blower and double filter 10 Technical specifications 10 1 General Aluminium construction Sunshield in ABS Epoxypolyester powder painting RAL9002 colour Stainless steel external screws Supplied with instruction manual desiccant bag accessories for camera and lens mounting 10 2 Mechanical Cable glands 3xM16 Glas...

Page 13: ...nual 11 11 Technical drawings j jThe values are in millimeters 76 98 27 131 160 213 70 40 188 113 60 88 88 400 225 13 39 39 62 140 53 514 176 100 70 250 70 A A B B A A B B 9 0 R100 400 430 412 USABLE AREA USABLE AREA Fig 14 HOV ...

Page 14: ...dquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Vicon Germany Kornstieg 3 D 24537 Neumuenster Phone 49 0 4321 8790 Fax 49 0 4321 879 97 Far East Office Unit 5 17 F Metropole Square 2 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon security com ...

Reviews: