5
DEMINERALIZATION CARTRIDGE ACA-817E
1. The durability and performance of the ACA-817E Cartridge (6)
depends on the mineral content of the water.
2. When using the humidifier under normal conditions the
Cartridge (6) should be replaced every 30 – 40 fillings.
Replace more often in hard water areas.
3. Replacement ACA-817E Cartridges (6) are available where you
purchased your humidifier.
4. Do
not
operate the humidifier
without
the Demineralization
Cartridge (6) and do not use an exhausted cartridge. In areas,
where water has a high hardness, there might be an output of
minerals, noticeable as “white dust” (see extra filters).
EXTRA FILTERS
In hard water areas, there might be an output of minerals,
noticeable as “white dust”. In order to determine the hardness of
the water you may ask your water company.
KF-520E K-Filter (sold separately)
1. If the hardness of the water is extremely high the cold tap
water should be filtered with the KF-520E K-Filter before
filling it into the Water Tank (6).
2. The KF-520E K-Filter reduces the calcium carbonate content
24of the water.
3. The KF-520E K-Filter can be regenerated and therefore has a
long lifetime.
4. Using the KF-520E K-Filter please carefully read and follow
the special instructions included in each filter package.
SF-530E A-Filter (sold separately)
1. The SF-530E A-Filter should be used when salt is added to the
water by use of a water softening plant. If the water has an
extremely high salt content the cold tap water should
first
be filtered with the SF-530E filter.
2.
Then
filter the water with the KF-520E K-Filter. The water,
filtered twice, can now be filled into the Water Tank (6).
3. The SF-530E A-Filter can be regenerated and therefore has a
long lifetime.
4. Using the SF-530E please carefully read and follow the special
instructions included in each filter package.
FILLING THE WATER TANK
1. Check that the Power Switch (12) is in the Off position and
that the plug and not plugged in.
2. Remove the Directional Mist Nozzle (1) from the
Water Tank (3).
3. Remove the Water Tank (3) from the Base (11) and turn it
upside down. Open the Tank Cap (4) by turning it
counter-
clockwise
.
4. Fill the Water Tank (3)
only
with clean, cool tap water
(approx. 6 litres). Do not use warm or hot water. This can
damage the Cartridge (6) and the Ultrasonic Nebulizer (10)
and void the warranty.
5.
Do not add any substances into the Water Tank (3) or
Reservoir (7) or onto the Cartridge (6) (e.g. inhalant,
aromatic substances etc.). This can cause health hazards.
6. Close the Water Tank (3) with the Tank Cap (4) by turning it
clockwise
.
7. Check that the Cartridge (6) is in place.
8. Turn the Water Tank (3) upright. Make sure that the Tank Cap
(4) is in place and check it for leaks.
9. Replace the filled Water Tank (3) on the Base (11) and the
Directional Mist Nozzle (1) into the Water Tank (3). Wait for
approx. 15 minutes before operating the humidifier, so
that the water can run through the Cartridge (6) into the
Reservoir (7).
SCENT PAD HEATER DIRECTIONS FOR USE:
Your Vicks Ultrasonic Humidifier includes a scent pad heater so
that you can enjoy Vicks soothing menthol vapors to increase
your comfort. Each scent pad is designed to last for 6-8 hours of
use.
1. Remove the water tank and locate the scent pad slot on the
base.
2. Place one scent pad in the slot, being careful not to touch the
scent pad with your hands. If your hands do come in contact
with the pad, please wash them thoroughly as the menthol
can be an irritant.
3. Replace the tank and turn the unit on.
Note:
As long as your humidifier is on, the scent pad heater will
also be activated. This area can be warm to the touch.
Replacing Pads:
1. Turn off and unplug your humidifier.
2. Remove tank and set aside.
3. Gently pull old scent pad out of the slot and discard.
4. Open refill pad and insert as described above.