Adjusting the filling grade 
Warning! 
Vicair B.V. recommends to adjust the 
filling grade under the direct supervision of your 
therapist or technical advisor. 

Ready for use 
This Vicair product is ready for use. It has its own 
unique filling grade, depending on size and 
model and automatically manages small 
obliquities. However – if necessary to support 
more extreme asymmetry – the filling grade can 
be adjusted by removing or adding SmartCells 
from/to the various compartments. You can find 
the default filling grade on the label attached to 
the cushion.

Conditions for use and storage 
Caution! 
Do not use or leave the product close 
to a naked flame or a high temperature heat 
source.
•  User weight:  

Minimum: 15 kg / 33 lbs,  
maximum: 250 kg / 551 lbs 

•  Temperature:  

Minimum: -20 °C / 4 °F,  
maximum: 55 °C / 131 °F

•  Use at high altitude  

Notice! Vicair B.V. recommends not to use 
the cushion above 2400 m (8000 ft) above 
sea level or below 50 m (164 ft) below sea 
level. Because each SmartCell is filled with 
air, the cushion may behave differently when 
used at high altitude or in an airplane. Under 
such circumstances, the cushion’s firmness 
can be adjusted by removing a few cells from 
each compartment. 

•  Air humidity:  

Minimum: 0%, maximum 100% 

Daily fluff-up 
Vicair B.V. recommends to fluff-up your Vicair 
cushion before use on a daily basis. 

Use of Vicair seat cushions in motor vehicles 
Warning!
 No testing data is currently available 
about the safe use of Vicair wheelchair cushions 
in motor vehicles. Therefore we do not 
encourage using the wheelchair cushion in 
motor vehicles. As an alternative for your Vicair 
wheelchair cushion, the Vicair AllRounder O2 
(which can be fastened to the user’s body) can 
be used if you require additional protection 
during transportation. 

Re-use - Transferring the product to another 
user 
The product is suitable for repeated use. 
The number of times it can be used depends on 
how often and in which way the product is used. 
The product has to be thoroughly cleaned and 
disinfected, before another person is allowed to 
use the it. See chapter ‘Maintenance and 
cleaning’ for instructions. 
Notice! Make sure the product is correctly 
adjusted to the other person.

Replacing the cushion cover 
Under normal use, Vicair B.V. recommends to 
replace the cushion cover every year. 
Replacement covers can be purchased 
separately.

Disposal 
The disposal and recycling of used devices and 
packaging must comply with the applicable legal 
regulation. Ensure the product is cleaned prior 
to disposal to avoid any risk of contamination.

MAINTENANCE AND CLEANING

Warning! Every three months, check the product 
for wear and deflated cells. In case of serious 
damage, or a large number of deflated cells, do 
not continue to use the product. Consult your 
dealer. 