VIA EPIA-P910 User Manual
26
5.2.
Installing into a Chassis
The VIA EPIA-P910 can be fitted into any chassis that has mounting holes compatible with the standard
Pico-ITX mounting hole locations. Additionally, the chassis must meet the minimum height requirements
for specified areas of the board.
5.2.1.
Suggested minimum chassis dimensions
The figure below shows the suggested minimum space requirements that a chassis should have in order to
work well with the VIA EPIA-P910.
Figure 30: Suggested minimum chassis dimensions
Each side of the board should have a buffer zone from the internal wall of the chassis. The side of the
board that accommodates the I/O coastline should have a buffer of 1.00mm. The side on the opposite
end of the I/O coastline should have a buffer of at least 5.00mm. The two sides adjacent to the I/O
coastline should have at least a 10.00mm buffer.
5.2.2.
Suggested minimum chassis height
The figure below shows the suggested minimum height requirements for the internal space of the chassis.
It is not necessary for the internal ceiling to be evenly flat. What is required is that the internal ceiling
height must be strictly observed for each section that is highlighted.
Figure 31: Suggested minimum internal chassis ceiling height
Note:
In getting the minimum height requirements for internal space of the chassis, it is required to consider the
heights of the connectors (such as SPI flash connector, CMOS battery connector and DDR3 SODIMM slot) on
the bottom side of the VIA EPIA-P910.