background image

14

MENU 4

The forth and final menu contains controls for some basic func-

tions and unit of measure settings.

SUPER RANGE

Super  Range  controls  the  way  the  display  appears  when  the 

depth range changes. When Super Range is OFF, and the range 

changes, you will see the point at which the range changed on the 

display. This point will scroll across the screen until it disappears 

at the far left side. When Super Range is ON, there will be no 

visible point at which the depth changed. Super Range adjusts 

the entire display to the new range.
To activate or disable the Super Range feature press...

 

MENU --> MENU --> MENU --> MENU (HOLD)

 

 

then      or      .

PULSE-LENGTH

Pulse Length controls how long each “ping” of the transducer is. 

Longer pulse lengths allow better deep water performance but 

reduce resolution. Shorter pulse lengths give the best resolution, 

but have problems reaching into deep water.
To change the Pulse Length press...

 

MENU --> MENU --> MENU --> MENU (HOLD)

 

 

then        and then       or       .

STC

STC stands for Surface Time Control. Its function is to reduce the 

surface clutter normally found in the first few feet of the water 

column by reducing the gain in this region.

To activate or disable STC press...

 

MENU --> MENU --> MENU --> MENU (HOLD)

 

 

then        -->       and then       or      .

DEPTH

The Depth feature controls how the digital depth number appears 

at the bottom of the display. Your choices are OFF, S (Small), or 

L (Large).  OFF  turns  off the  digital  depth  and all  other  digital 

indications. Small displays the digital depth and other indicators. 

Large makes the digital depth appear larger and easier to read. 

The other indicators stay the same size.

To change the Depth setting press...

 

MENU --> MENU --> MENU --> MENU (HOLD)

 

 

then        -->       -->        and then       or      .

DEPTH-UNIT

This feature lets you choose between Meters and Feet for depth 

measurement.

To change the Depth-Unit setting press...

 

MENU --> MENU --> MENU --> MENU (HOLD)

 

 

then        -->       -->        -->         

 

 

 

and then       or      .

TEMP-UNIT

This feature lets you choose between Celsius and Fahrenheit.

To change the Depth-Unit setting press...

 

MENU --> MENU --> MENU --> MENU (HOLD)

 

 

then        -->       -->        -->       

 

 

 

and then       or      .

Summary of Contents for EDGE 3

Page 1: ...1 Edge3 Color LCD Depth Sounder Model LC 507C Owner s Manual...

Page 2: ...y being able to cover a lot of area and reach into deep water much more ef ciently Lower frequencies also tend to lter out targets of very small size 400 kHz Depth Sounder The other half of the Edge3...

Page 3: ...a new Mode your setting for the last Mode are saved A common practice is to set up your modes the way you want and from then on simply turn the unit on and switch between your Modes SPECS FEATURES Dis...

Page 4: ...ack wire to negative If the cord pro vided is not long enough more can be added Use 18 gauge wire minimum Install a 2 amp in line fuse placed in the positive line as close to the power source as possi...

Page 5: ...rsed the until will not operate properly After you have put the boat back in the water confirm that you can maintain a bottom reading at all boat speeds If not loosen the bracket screws and tilt the t...

Page 6: ...oth spot near the center of the bilge and near the back of the boat It is a good idea to make a test run before you permanently install each transducer This makes sure that you can indeed get a readin...

Page 7: ...he Edge3 s display will be set up in the split screen mode with the 107 kHz beam on one side and the 400 kHz beam on the other Scattered around the display are some items offering information Refer to...

Page 8: ...Clean Line Level Right Beam Red Lens No Function Alarm Speaker Beam Select for Clean Line Control Clean Line Level Control Menu Cursor Navigation Keys Clean Line Level Left Beam Signal Strength Key M...

Page 9: ...the Automatic Range Control feature When Auto Range is on an R will show at the top of each beam display The Auto Range features maintains the best view of the bottom according to the A RNG MODE menu...

Page 10: ...conditions but more power is required To change the brightness press MENU or MENU 2 The settings on this menu affect each mode so only the currently active mode will retain the setting changes Menu 2...

Page 11: ...is setting controls the frequency of the beam for the left side of the display or to activate full screen mode Full screen mode is activated when you select N A The frequency of the single beam is det...

Page 12: ...items such as the display color zoom and the temperature alarm The settings on this menu affect all Modes BACK GRD This setting changes the color of the display s background Choose a background color...

Page 13: ...d corresponds to the bottom display This allows you to easily see where the bottom content changes To activate or disable Hard Bottom Level press MENU MENU MENU then or COMPOSITE Composite mode places...

Page 14: ...Pulse Length press MENU MENU MENU MENU HOLD then and then or STC STC stands for Surface Time Control Its function is to reduce the surface clutter normally found in the rst few feet of the water colu...

Page 15: ...stem Reset will cause the lose of all modi ed settings ACCESSORIES REPLACEMENT PARTS Depth TBX071 107 kHz Transducer 79 00 TBX072 400 kHz Transducer 79 00 CB0001 10 Transducer Extension Cable 24 00 CB...

Page 16: ...still or at slow trolling speeds but loses reading when the boat speeds up Improper transducer instal lation or adjustment Loss of clear water flow across the face of the transducer when the boat reac...

Reviews: