A-GAIN-LEVEL

Automatic  Gain  Level  configures  how  the  system  controls  the 

gain level when the Auto-Gain feature is on. “L” keeps the gain 

control on the lower side, “M” keeps it near the middle, and “H” 

keep the gain high.
To change the A-GAIN-LEVEL for the right beam press...

 

MENU --> MENU-->       -->       -->       

 

 

then      or      .

A-MODE

This setting places a vertical display at the right side of the beam 

view which shows an “instantaneous” view of current informa-

tion. It does not speed up the update rate of the unit, but it does 

allow you to recognize changes more quickly than the normal 

view, especially at lower sweep speeds.
To activate or disable A-Mode for the right beam press...

 

MENU --> MENU-->       -->       -->       -->      

 

 

then      or      .

FISH ALARM

The fish alarm will sound an audible alarm when the unit detects 

an object that is not part of the bottom. You can set it to sound on 

small “S” or only larger targets “L”.

To active or disable A-Mode for the right beam press...

 

MENU --> MENU-->       -->       -->       -->      -->      

 

 

then      or      .

LEFT

This setting controls the frequency of the beam for the left side 

of the display, or to activate full screen mode. Full screen mode 

is activated when you select “N/A”. The frequency of the single 

beam is determined by the RIGHT selection.
To change the frequency for the left beam press...

 

MENU --> MENU-->       -->       -->       -->      -->      -->       

 

 

then      or      .

SWEEP

This setting controls how fast the display moves across the screen, 

and how fast the Edge3 transmits each pulse. There are five set-

tings from Stopped to 4. For the most accurate representation of 

what’s below you, choose a setting that as closely matches the 

boat’s speed as you can.
To change the sweep speed for the left beam press...

 

MENU --> MENU-->       -->       -->       -->      -->     

 

 

then      or      .

A-RNG-MODE

Automatic  Range  Mode  controls  how  the  Auto-Range  feature 

maintains the view of the bottom. It only applies when the Auto-

Range feature is on. 1ST configures the system to maintain the 

best  view  of  the  bottom.  2ND  configures  the  system  to  make 

sure the range setting is adjusted deeper, so you can always see a 

second bottom echo. 3RD insures the system will allow room for 

a third echo.
To change the A-RANGE-MODE for the left beam press...

 

MENU --> MENU -->       -->       -->       -->

 

 

then        or      .

Summary of Contents for EDGE 3

Page 1: ...1 Edge3 Color LCD Depth Sounder Model LC 507C Owner s Manual...

Page 2: ...y being able to cover a lot of area and reach into deep water much more ef ciently Lower frequencies also tend to lter out targets of very small size 400 kHz Depth Sounder The other half of the Edge3...

Page 3: ...a new Mode your setting for the last Mode are saved A common practice is to set up your modes the way you want and from then on simply turn the unit on and switch between your Modes SPECS FEATURES Dis...

Page 4: ...ack wire to negative If the cord pro vided is not long enough more can be added Use 18 gauge wire minimum Install a 2 amp in line fuse placed in the positive line as close to the power source as possi...

Page 5: ...rsed the until will not operate properly After you have put the boat back in the water confirm that you can maintain a bottom reading at all boat speeds If not loosen the bracket screws and tilt the t...

Page 6: ...oth spot near the center of the bilge and near the back of the boat It is a good idea to make a test run before you permanently install each transducer This makes sure that you can indeed get a readin...

Page 7: ...he Edge3 s display will be set up in the split screen mode with the 107 kHz beam on one side and the 400 kHz beam on the other Scattered around the display are some items offering information Refer to...

Page 8: ...Clean Line Level Right Beam Red Lens No Function Alarm Speaker Beam Select for Clean Line Control Clean Line Level Control Menu Cursor Navigation Keys Clean Line Level Left Beam Signal Strength Key M...

Page 9: ...the Automatic Range Control feature When Auto Range is on an R will show at the top of each beam display The Auto Range features maintains the best view of the bottom according to the A RNG MODE menu...

Page 10: ...conditions but more power is required To change the brightness press MENU or MENU 2 The settings on this menu affect each mode so only the currently active mode will retain the setting changes Menu 2...

Page 11: ...is setting controls the frequency of the beam for the left side of the display or to activate full screen mode Full screen mode is activated when you select N A The frequency of the single beam is det...

Page 12: ...items such as the display color zoom and the temperature alarm The settings on this menu affect all Modes BACK GRD This setting changes the color of the display s background Choose a background color...

Page 13: ...d corresponds to the bottom display This allows you to easily see where the bottom content changes To activate or disable Hard Bottom Level press MENU MENU MENU then or COMPOSITE Composite mode places...

Page 14: ...Pulse Length press MENU MENU MENU MENU HOLD then and then or STC STC stands for Surface Time Control Its function is to reduce the surface clutter normally found in the rst few feet of the water colu...

Page 15: ...stem Reset will cause the lose of all modi ed settings ACCESSORIES REPLACEMENT PARTS Depth TBX071 107 kHz Transducer 79 00 TBX072 400 kHz Transducer 79 00 CB0001 10 Transducer Extension Cable 24 00 CB...

Page 16: ...still or at slow trolling speeds but loses reading when the boat speeds up Improper transducer instal lation or adjustment Loss of clear water flow across the face of the transducer when the boat reac...

Reviews: