www.fmiproducts.com
123095-01C
31
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information,
page 30.
2. Open lower louver panel.
3. Turn off all electric power to fireplace.
4. Push in gas control knob slightly and turn
clockwise
to OFF.
5. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the
floor. If you smell gas, STOP! Follow “B”
in the safety information, page 30. If you
don't smell gas, go to the next step.
6. The pilot is located by the main burner and
should not require accessing for lighting.
7. Turn gas control knob counterclockwise
to PILOT (see Figure 55).
8. Push in gas control knob all the way and
hold. Immediately light pilot by repeatedly
pressing piezo spark ignitor until a flame
appears. Continue to hold for about one
(1) minute after pilot is lit. Release gas
control knob and it will pop back. Pilot
should remain lit. If it goes out, repeat
steps 5 through 9.
• If gas control knob does not pop up when
released, stop and immediately call your
service technician or gas supplier.
• If pilot will not stay lit after several tries,
turn gas control knob to OFF and call
your service technician or gas supplier.
9. Turn on all electric power to fireplace.
10. Turn gas control knob counterclockwise
to ON.
11. This valve is equipped with a HI/LO fea-
ture. Set fireplace input as desired.
OFF
P
IL
O
T
ON
LO
HI
P
ILOT
E
A
16AI
7
TPTH
TP
TH
Gas Control
Knob
Flame Adjustment
Knob
Position
Indicator
Figure 55 - Millivolt Control Valve
Figure 56 - Pilot
Thermopile
Pilot Burner
Piezo Ignitor
Thermocouple
OPERATION
Continued
TO TURN OFF GAS
TO APPLIANCE
1. Open lower louver panel.
2. Set selector switch in the OFF position to
prevent draining battery.
3. Turn off all electrical power to appliance
if service is to be performed.
4. Push in gas control knob slightly and turn
clockwise
to OFF.
5. Close lower louver panel.
12. Close lower louver panel.
13. To leave pilot lit and shut off burners only,
turn control knob clockwise
to the
PILOT position or set selector switch in
the OFF position.
**For purpose of input adjustment.
SPECIFICATIONS
FUEL: NATURAL GAS)
• Input Rating: 35,000/23,300 Btu/Hr
• Manifold Pressure: 3.5" W.C.
• Minimum Supply Pressure: 4.5 W.C. **
• Maximum Supply Pressure: 10.5" W.C.
• Orifice Size (0-4500 ft.): #34 DMS
FUEL: PROPANE/LP GAS
• Input Rating: 31,000/20,000 Btu/Hr
• Manifold Pressure: 10" W.C.
• Minimum Supply Pressure: 11 W.C. **
• Maximum Supply Pressure: 13" W.C.
• Orifice Size (0-4500 ft.): #51 DMS