www.fmiproducts.com
123095-01C
28
BURNER FLAME ADJUSTMENT
Figure 51 - Burner Flame Patterns
Figure 50 - Air Shutter Adjustment
Air Shutter Air
Opening
Burner
Venturi
Tube
Burner Gas Line
CORRECT
INCORRECT
CLOSE
SHUTTER
INCORRECT
OPEN SHUTTER
Short, Sharp, Blowing Flame
Long, Blue Flame with
Yellow Tips
Long, Uneven, Yellow Flame
Firebox Bottom
Adjustment
Screw
Orifice
The air shutter, located at the base of the
main burner (see Figure 50), has been fac-
tory preset to the proper air-to-gas ratio which
results in an even, clean burning flame across
the burner (see Figure 51). If readjustment is
necessary, you can restore the proper air-to-
gas ratio by loosening the air shutter screw
and rotating the air shutter until the proper
flame setting is achieved (the shutter's normal
setting is fully open. Do not forget to retighten
the air shutter screw.
Figure 52 - Burner Removal
BURNER REMOVAL
CAUTION: Before proceeding
to open glass door or handle logs,
make sure entire unit is cool.
1. Remove top and bottom louvers and
screen assembly. Undo 4 latches and
open glass door.
2. Carefully remove log set intact and set
aside (see Figure 52).
3. Remove 2 screws holding burner to hearth
pan.
4. Slide burner forward off orifice and turn to
one side to clear opening in hearth pan.
Be careful not to bend or damage pilot or
ignitor element.
5. To reinstall burner, follow reverse steps
making sure air shutter on burner tube is
completely seated over orifice mount.
6. Replace log set. Close door and latch.
Reattach screen and louvers.
CAUTION: Make certain ori
-
fice is fully inside venturi tube's
air shutter and that air shutter
is adjusted accordingly, see
Figure 50.
Glass Door
Refractories
Grate and
Logs
Burner
Hearth Pan
Louver
Assembly
f i r e - p a r t s . c o m