INSTALLATION

 WARNING: Read all instruc-

tions completely and thoroughly 

before  attempting  installation. 

Failure to do so could result in 

serious  injury,  property  dam-

age or loss of life. Operation of 

improperly installed and main-

tained  venting  system  could 

result in serious injury, property 

damage or loss of life.

NOTICE: Failure to follow these in-

structions will void the warranty. 

VENTING INSTALLATION 
PRECAUTIONS

Consult local building codes before beginning the 

installation. The installer must make sure to select 

the proper vent system for installation. Before 

installing  vent  kit,  the  installer  must  read  this 

fireplace manual and vent kit instructions.
Only  a  qualified  service  person  should  install 

venting system. The installer must follow these 

safety rules:
•  Wear gloves and safety glasses for protection
•  Use extreme caution when using ladders or 

when on roof tops

•  Be aware of electrical wiring locations in walls 

and ceilings

The following actions will void the warranty on 

your venting system:
•  Installation of any damaged venting component
•  Unauthorized modification of the venting system
•  Installation of any component part not manu-

factured or approved by DESA 

•  Installation other than as instructed by these 

instructions

 WARNING: This gas fireplace 

and  vent  assembly  must  be 

vented directly to the outside. The 

venting system must NEVER be 

attached to a chimney serving a 

separate solid fuel burning appli-

ance. Each gas appliance must 

use a separate vent system. Do 

not use common vent systems.

  WARNING:  Horizontal  sec-

tions of this vent system require 

a minimum clearance of 2" from 

the top of the pipe and 1" mini-

mum to the sides and bottom. 

Vertical sections of this system 

require a minimum of 1" clear-

ance  to  combustible  materials 

on all sides of the pipe.

VENTING INSTALLATION

1.  Install elbow to fireplace collar adapter located 

on back of the unit at a 45° angle. Slide elbow 

over collar and twist to lock. Check to insure 

proper connection (see Figure 6).

2.  Continue  to  install  remainder  of  pipe  for 

desired installation. Make sure each section 

is twist-locked securely.

3.  When installation of vent pipe is complete, in 

stall vent termination. Depending on the loca-

tion of your fireplace, you will vent vertically 

or horizontally. 

4.  Allow 1" of pipe to protrude from internal 

wall,  depending  on  wall  thickness.  See 

Figure 7, page 8.

5.  For horizontal installation, an optional siding 

standoff may be installed between the vent cap 

and the exterior wall. Secure horizontal vent cap 

to standoff. Secure standoff/vent cap assembly 

to wall (see Figure 7, page 8). Do not seal termi-

nation to vent pipe. The vent termination must 

be removable for service pipe inspection. 

Figure 6 - Venting Installation

Female 
Locking Lugs

Male 
Locking Lugs

Vertical Flue 
Restrictor 
(For Vertical 
Venting 
Application)

Summary of Contents for CD32Ml

Page 1: ...h do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the re department Installa...

Page 2: ...d the Manufactured Home Construction and Safety Stan dard Title 24 CFR Part 3280 in the United States or the Mobile Home Standard CAN CSA Z240 MH Series in Canada This replace is only for use with the...

Page 3: ...uring safe and continuous operation of the replace Consult the local building codes as to the particular requirements concerned with the instal lation of all factory built replaces This replace when i...

Page 4: ...N PREPARATION CAUTION Do not block required air spaces with insula tionoranyothermaterial Donot obstruct the effective opening of the appliance with any type of facing material CLEARANCES TO COMBUSTIB...

Page 5: ...which could cause a re WARNING Horizontal sec tions of this vent system require a minimum clearance of 2 from the top of the pipe and 1 mini mum to the sides and bottom Vertical sections of this syste...

Page 6: ...ved driveway located on public property 84 inches 213 4cm minimum M clearance under veranda porch deck 12 inches 30 5cm minimum N clearance above a roof shall extend a minimum of 24 inches 61cm above...

Page 7: ...bly must be venteddirectlytotheoutside The venting system must NEVER be attached to a chimney serving a separatesolidfuelburningappli ance Each gas appliance must use a separate vent system Do not use...

Page 8: ...mination that is over 3 ft support the pipe every 3 ft using metal wall straps Vertical to horizontalpipemustbekeptata1ft to4ft ratio with a maximum run of no more than 20 ft If an offset is necessary...

Page 9: ...in excess of 1 2 psig 3 5 kPa The appliance must be isolated from the gas sup ply piping system by closing its individual shutoff valve during any pressure testing of the gas supply piping system at...

Page 10: ...a leak Correct all leaks at once Do not operate any appliance if a leak is detected INSTALLATION Continued Figure 13 Gas Line Routing Gas Routing Right Side Not Shown Side of Fireplace Front Face Figu...

Page 11: ...place Models CD32M and CD36M A Series 1 Place log 1 back log on top of grate as shown in Figure 18 for the CD36M A Series Log 1 will go in front of the metal partition on grate see Figure 18 Make sure...

Page 12: ...log 3 rear log onto pins on rear of grate see Figure 25 4 Place log 4 crossover log onto pins from both logs 2 and 3 see Figure 26 Figure 23 Installing Log 1 Model CD42M A Figure 24 Installing Log 2 M...

Page 13: ...els must remain accessible for service Use only heat re sistant noncombustible mortar or adhesive when securing decorative facing materials FACE EXTENSION FOR MODEL CD32M ONLY Model CD32M comes equipp...

Page 14: ...necessary Turn off gas and remote switch before servicing appliance Any safety screen or guard removed for servicing the replace must be replaced prior to operation Have a quali ed agency periodically...

Page 15: ...etting 12 Turn on all electric power to the appliance Note It is recommended that you maintain the gas control knob in the full OFFposition during lengthy periods of seasonal non usage OPERATING FIREP...

Page 16: ...ll the identi cation label enclosed with gas valve regulator to the valve body where it can easily be seen see Figure 36 WARNING Theconversionkit must be installed by a quali ed servicetechnicianinacc...

Page 17: ...ement on thermocouple 3 Ensure the connection be tween valve and thermocouple are tight and secure 4 Check thermocouple with millivolt meter Take reading at thermocouple terminals of gas valve with re...

Page 18: ...1916 01F 18 6 7 19 18 10 12 23 24 34 2 11 17 8 21 2 21 6 21 4 21 5 21 3 21 1 1 13 9 16 3 14 4 20 15 5 15 42 40 35 36 22 37 39 38 25 41 26 30 27 28 29 33 31 32 ILLUSTRATED PARTS BREAKDOWN MODELS CD32M...

Page 19: ...ssover Log Log 4 1 21 5 109405 01 107348 01 Left Top Log Log 5 1 21 6 109408 01 107347 01 Right Top Log Log 6 1 22 11102 11102 Screw 8 32 x 3 8 PPH Zinc 2 23 11105 11105 Screw 10 x 1 2 Zinc 9 24 11179...

Page 20: ...com 111916 01F 20 ILLUSTRATED PARTS BREAKDOWN MODEL CD42M A 37 23 41 42 38 22 39 32 31 33 28 26 25 29 24 34 35 40 36 30 27 28 6 7 19 18 10 12 2 11 17 8 20 1 4 13 16 3 14 15 5 15 9 212 21 3 21 6 21 7 2...

Page 21: ...over Log Log 4 1 21 5 109399 01 Top Center Log Log 5 1 21 6 109400 01 Top Left Log Log 6 1 21 7 109401 01 Top Right Log Log 7 1 22 11102 Screw 8 32 x 3 8 PPH Zinc 2 23 11105 Screw 10 x 1 2 Zinc 9 24 1...

Page 22: ...P Manifold Pressure 10 w c 10 w c 10 w c Minimum Inlet Supply Pressure 4 5 w c 4 5 w c 4 5 w c WIRING DIAGRAM Thermocouple Incoming Main Gas Supply Piezo Ignitor Control Valve Electrical Rating 120v 6...

Page 23: ...2M 109479 01 CD32M SERIES BK BLOWER KIT REGULAR TRANSMITTER TRANSMITTER RECEIVER RECEIVER TRANSMITTER STANDARD REMOTE CONTROL KIT P N 14187 MILLIVOLT ONLY RECEIVER AND TRANSMITTER RECEIVER P N 00825 E...

Page 24: ...2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 www desatech com NOT A UPC 111916 01 Rev F 04 05 111916 01...