INTRODUCTION

 WARNING: This product con-

tains and/or generates chemicals 

known to the State of California 

to cause cancer or birth defects 

or other reproductive harm.

Models  CD32M  series,  CD36M-A  series  and 

CD42M-A  series  are  heat  circulating  grav-

ity direct-vent fireplaces with sealed combustion 

chamber. These fireplaces use millivolt gas control 

valve and millivolt ignition system.
These fireplaces are convertible with the standard 

setup as natural gas. Conversion may be performed 

by the O.E.M. mobile home builder or by a quali-

fied service person on-site. If you are uncertain as 

to what gas your unit is equipped for, please check 

the rating plate located inside of the appliance 

opening or consult your mobile home supplier or 

your local distributor of DESA/Vexar products.

NOTICE:  Check  local  building 

codes for area requirements be-

fore installing this appliance.

BEFORE YOU BEGIN

Before beginning the installation of your appli-

ance, read these instructions through completely.
This DESA/Vexar fireplace and its components are 

safe when installed according to this installation 

manual and operated as recommended. Unless 

you use DESA/Vexar components designed and 

tested for this fireplace system, 

YOU MAY CAUSE 

A SAFETY HAZARD!

The DESA/Vexar warranty will be voided by, and 

DESA/Vexar disclaims any responsibility for the 

following actions:
A) Modification  to  the  fireplace,  components, 

doors, blower, fans or vent system.

B) Use of any component part not manufactured or 

approved by DESA/Vexar in combination with 

a DESA/Vexar fireplace system.

Proper installation is the most important step in 

ensuring  safe  and  continuous  operation  of  the 

fireplace. Consult the local building codes as to the 

particular requirements concerned with the instal-

lation of all factory built fireplaces. This fireplace, 

when installed, must be electrically grounded in 

accordance with local codes or in the absence of 

local codes, with the 

National Electrical Code, 

ANSI/NFPA 70

 or the 

Canadian Electrical Code, 

CSA C22.1.

The installation must conform with local codes or, 

in the absence of local codes, with the 

National Fuel 

Gas Code, ANSI Z223.1

 or the 

Canadian Installa-

tion Code, CAN/CGA B149.

 This appliance com-

plies with ANSI Z21.88-1998 and CSA 2.33-M98 

as a VENTED GAS FIREPLACE HEATER. 

SELECTING LOCATION

To determine the safest and most efficient loca-

tion  for  your  fireplace,  consider  the  following 

guidelines:
1.  The location must allow for proper clearances 

(see Figure 1).

2.  Consider a location where the fireplace would 

not  be  affected  by  drafts,  air  conditioning 

ducts, windows or doors.

3.  A location that avoids the cutting of joists or roof 

rafters makes ventilation installation easier.

In selecting a location, the following precautions 

must be observed:
•  Do not connect this appliance to a chimney 

system used for solid fuel burning fireplace.

•  Due to high temperatures, do not locate this 

appliance in high traffic areas or near furniture 

and draperies.

•  Never obstruct the openings of the appliance 

or  flow  of  ventilation  air.  Keep  the  control 

compartments accessible.

Figure 1 - Common Fireplace Locations

FULL

PROJECTION

CORNER

INSTALLATION

FLUSH

INSTALLATION

Flush installation

 is recommended where living 

space is limited.

Projected installation

 may be ideal for a new 

addition to an existing finished wall.

Corner installation

 makes use of a space that may 

not normally be used and provides a wider and 

more efficient range for radiant heat transfer.

Summary of Contents for CD32Ml

Page 1: ...h do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the re department Installa...

Page 2: ...d the Manufactured Home Construction and Safety Stan dard Title 24 CFR Part 3280 in the United States or the Mobile Home Standard CAN CSA Z240 MH Series in Canada This replace is only for use with the...

Page 3: ...uring safe and continuous operation of the replace Consult the local building codes as to the particular requirements concerned with the instal lation of all factory built replaces This replace when i...

Page 4: ...N PREPARATION CAUTION Do not block required air spaces with insula tionoranyothermaterial Donot obstruct the effective opening of the appliance with any type of facing material CLEARANCES TO COMBUSTIB...

Page 5: ...which could cause a re WARNING Horizontal sec tions of this vent system require a minimum clearance of 2 from the top of the pipe and 1 mini mum to the sides and bottom Vertical sections of this syste...

Page 6: ...ved driveway located on public property 84 inches 213 4cm minimum M clearance under veranda porch deck 12 inches 30 5cm minimum N clearance above a roof shall extend a minimum of 24 inches 61cm above...

Page 7: ...bly must be venteddirectlytotheoutside The venting system must NEVER be attached to a chimney serving a separatesolidfuelburningappli ance Each gas appliance must use a separate vent system Do not use...

Page 8: ...mination that is over 3 ft support the pipe every 3 ft using metal wall straps Vertical to horizontalpipemustbekeptata1ft to4ft ratio with a maximum run of no more than 20 ft If an offset is necessary...

Page 9: ...in excess of 1 2 psig 3 5 kPa The appliance must be isolated from the gas sup ply piping system by closing its individual shutoff valve during any pressure testing of the gas supply piping system at...

Page 10: ...a leak Correct all leaks at once Do not operate any appliance if a leak is detected INSTALLATION Continued Figure 13 Gas Line Routing Gas Routing Right Side Not Shown Side of Fireplace Front Face Figu...

Page 11: ...place Models CD32M and CD36M A Series 1 Place log 1 back log on top of grate as shown in Figure 18 for the CD36M A Series Log 1 will go in front of the metal partition on grate see Figure 18 Make sure...

Page 12: ...log 3 rear log onto pins on rear of grate see Figure 25 4 Place log 4 crossover log onto pins from both logs 2 and 3 see Figure 26 Figure 23 Installing Log 1 Model CD42M A Figure 24 Installing Log 2 M...

Page 13: ...els must remain accessible for service Use only heat re sistant noncombustible mortar or adhesive when securing decorative facing materials FACE EXTENSION FOR MODEL CD32M ONLY Model CD32M comes equipp...

Page 14: ...necessary Turn off gas and remote switch before servicing appliance Any safety screen or guard removed for servicing the replace must be replaced prior to operation Have a quali ed agency periodically...

Page 15: ...etting 12 Turn on all electric power to the appliance Note It is recommended that you maintain the gas control knob in the full OFFposition during lengthy periods of seasonal non usage OPERATING FIREP...

Page 16: ...ll the identi cation label enclosed with gas valve regulator to the valve body where it can easily be seen see Figure 36 WARNING Theconversionkit must be installed by a quali ed servicetechnicianinacc...

Page 17: ...ement on thermocouple 3 Ensure the connection be tween valve and thermocouple are tight and secure 4 Check thermocouple with millivolt meter Take reading at thermocouple terminals of gas valve with re...

Page 18: ...1916 01F 18 6 7 19 18 10 12 23 24 34 2 11 17 8 21 2 21 6 21 4 21 5 21 3 21 1 1 13 9 16 3 14 4 20 15 5 15 42 40 35 36 22 37 39 38 25 41 26 30 27 28 29 33 31 32 ILLUSTRATED PARTS BREAKDOWN MODELS CD32M...

Page 19: ...ssover Log Log 4 1 21 5 109405 01 107348 01 Left Top Log Log 5 1 21 6 109408 01 107347 01 Right Top Log Log 6 1 22 11102 11102 Screw 8 32 x 3 8 PPH Zinc 2 23 11105 11105 Screw 10 x 1 2 Zinc 9 24 11179...

Page 20: ...com 111916 01F 20 ILLUSTRATED PARTS BREAKDOWN MODEL CD42M A 37 23 41 42 38 22 39 32 31 33 28 26 25 29 24 34 35 40 36 30 27 28 6 7 19 18 10 12 2 11 17 8 20 1 4 13 16 3 14 15 5 15 9 212 21 3 21 6 21 7 2...

Page 21: ...over Log Log 4 1 21 5 109399 01 Top Center Log Log 5 1 21 6 109400 01 Top Left Log Log 6 1 21 7 109401 01 Top Right Log Log 7 1 22 11102 Screw 8 32 x 3 8 PPH Zinc 2 23 11105 Screw 10 x 1 2 Zinc 9 24 1...

Page 22: ...P Manifold Pressure 10 w c 10 w c 10 w c Minimum Inlet Supply Pressure 4 5 w c 4 5 w c 4 5 w c WIRING DIAGRAM Thermocouple Incoming Main Gas Supply Piezo Ignitor Control Valve Electrical Rating 120v 6...

Page 23: ...2M 109479 01 CD32M SERIES BK BLOWER KIT REGULAR TRANSMITTER TRANSMITTER RECEIVER RECEIVER TRANSMITTER STANDARD REMOTE CONTROL KIT P N 14187 MILLIVOLT ONLY RECEIVER AND TRANSMITTER RECEIVER P N 00825 E...

Page 24: ...2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 www desatech com NOT A UPC 111916 01 Rev F 04 05 111916 01...

Reviews: