Battery charger / inverter COMBI-GAMMA
72
090138.02
U2-04: AC IN Current
Use constant U2-04 to monitor the AC input current value in units of 0.1A when the cur-
•
rent fault occurs.
U2-05: AC OUT Voltage
Use constant U2-05 to monitor the AC output voltage value in units of 0.1V when the
•
current fault occurs.
U2-06: AC OUT Current
Use constant U2-06 to monitor the AC output current value in units of 0.1A when the
•
current fault occurs.
U2-07: Battery Voltage
Use constant U2-07 to monitor the battery voltage value in units of 0.1V when the current
•
fault occurs.
U2-08: Battery Ripple Volt
Use constant U2-08 to monitor the battery ripple voltage in units of 0.1V when the cur-
•
rent fault occurs.
U2-09: Battery Current
Use constant U2-09 to monitor the battery current value in units of 0.1A when the current
•
fault occurs.
U2-10: Control Mode
Use constant U2-10 to monitor what the control mode (MODE 1, MODE 2, MODE 3 or
•
MODE 4) is when the current fault occurs.
U2-11: Operation Status
Use constant U2-11 to monitor 12 digits which account for each operation status when
•
the current fault occurs. Please see NOTE 1 in Chapter 5.
U2-12: Aux-Relay Status
Use constant U2-12 to monitor the ON/OFF status of 3 sets of Aux-Relay (RY1, RY2,
•
RY3) when the current fault occurs. Please see NOTE 2 in Chapter 5.
U2-13: Elapsed Time
Use constant U2-13 to monitor the elapsed time after power ON (O2-03=0) or after RUN
•
(O2-03=1) in unit of 1 hour when the current fault occurs.