![Vetter 1500005102 Operating Instructions Manual Download Page 8](http://html.mh-extra.com/html/vetter/1500005102/1500005102_operating-instructions-manual_1010255008.webp)
Vetter Leak Sealers
Page 8/39
Compressed air bottle
3.2
Operation of the controller, inflation hose and
other sources of compressed air
Observe the maximum input pressures of the
controllers for the various pressures
(refer to the table below).
Applied pressure
Maximum input pressure of
the controller
0.5 bar
2 bar
1.0 bar
2 bar
1.5 bar
2 bar
2.5 bar
4 bar
12.0 bar
14 bar
Adapters contained in the adapter kit
The adapter kit contains adapters for the following sources of
compressed air:
Truck compressed air connection with blind coupling
Close the control line to the blind coupling.
The tyre inflation connection must be secured with a safety valve
as a standard.
The control line is to be connected with the blind coupling. The
truck must be secured by brake holding blocks so that it does not
roll away.
Local compressed air network
Connection to the outlet coupling of a compressed air network.
Series connected pressure regulator, max input pressure
of 16 bar
If the output pressure of the compressed air network exceeds the
permitted inflation pressure of the controller then the adapter
must be exchanged for a series connected pressure regulator.
Truck compressed
air connection
Blind coupling