10. Vetter Vacuum Leak Draining Bag
10.1 Vacuum Leak Draining Bag DLD 50 VAC
The Vetter vacuum leak draining bag DLD 50 VAC enables beltless
sealing of leaks on tank wagons and tanker trucks as well as large
containers and tanks. The vacuum leak draining bag DLD 50 si-
multaneously seals leaks and drains the liquid(s) into a collection
tank via the drainage chamber.
10.2 Safety instructions
Observe the pertinent regulations when handling dan-
gerous liquids. Danger of explosion! If there are inflam-
mable liquid or gas leaks it is imperative that sparks be
avoided by fixtures and fittings.
9
Before operation check to see if the vacuum leak sealing bag
is resistant against the hazardous material (refer to the resis-
tance chart).
9
Wear the specified protective clothing required for operati-
on.
9
The sealing of the vacuum leak draining bag is dependent on
the condition of the tank wall. Therefore under certain condi-
tions it is necessary to permanently renew the vacuum.
9
Therefore take care of a suffcient and permanent air supply.
9
It is therefore necessary to use the Vetter adapter 12 bar (Art.
No. 1600015400) for operation with compressed air bottles.
10.3 Application instructions
9
Connect the pressure regulator to the compressed air bottle.
9
Close the outlet valve (1) by turning clockwise.
9
Open the valve on the bottle (2) slowly.
9
Pre-pressure manometer indicates the pressure in the bottle
(3).
9
Adjust the back-pressure to 6 bar using the adjustment lever
(4).
9
The reduced pressure is indicated on the back-pressure ma-
nometer (5).
9
The vacuum leak draining bag can only be used on areas ha-
ving only a slight curvature and a smooth structure.
9
The container surface must be clean.