![Vetter 1500005102 Operating Instructions Manual Download Page 7](http://html.mh-extra.com/html/vetter/1500005102/1500005102_operating-instructions-manual_1010255007.webp)
Page 7/39
3.
Operation of the Leak Sealers
This chapter gives you information about which sources of com-
pressed air you are able to use with Vetter leak sealers.
When using leak sealers observe the
corresponding pressure stage.
3.1
Operation with controllers, inflation hose and
compressed air bottle
As an example the following pictures present
the sequence of events for leak sealing
bags 1.5 bar. Corresponding leak sealers
and accessories must be used for other
pressures and other sources of air.
Before inflation, the leak sealing bags
must be correctly and safely tensioned
with tension belts on the leak position.
To do this, refer to Chapter 4.3 “Handling the tension rat-
chet”.
Leak sealing bag
9
Step
1
Connect the leak sealing bag LD 50/30 S 1.5 bar with guide
slots to the inflation hose.
Inflation hose
9
Step
2
Connect the inflation hose to the controller.
Controller
9
Step
3
Connect the connection hose of the pressure regulator to
the input coupling of the controller. It is imperative that the
permitted input pressure of the controller be observed when
doing this.
Pressure regulator
9
Step 4
Screw the pressure regulator into the valve on the compressed
air bottle.