background image

4

SPECIFICATIONS

Power Source……………………………………………..1x9V

Unit of measurement…………………………….Feet or Meters

Accuracy………………………………………….0.5%

±

1digit (8~60ft)

1%

±

1digit (2~8ft)

Working Frequency……………………………………….40kHz

Working Temp…………………32

°

to 109.4

°

F(0

°

to 43

°

C)

Range…………………………………2 to 60ft (0.61 to 18.288m)

Specifications are typical; individual units might vary. Specifications are

subject to change and improvement without notice.

Caution:

The laser emitted from the unit is visible laser of 650nm
wavelength

Don’t stare into the laser beam and also don’t shoot laser beam
to any other’s eyes.

Class

laser product Output < 1mw

Notes:

The product has passed EN60825-1: 1994 + A11: 1996

21CFR 1040.10 & 1040.11

Corresponding label is affixed on the back of the unit

.

Summary of Contents for E5020503

Page 1: ...G THE MEASURER Your measurer is sensitive to changes in temperature and humidity Before you use the measurer wait about 15 30 minutes for it to stabilize to the current room s temperature OPERATION TURNING THE MEASURER ON OFF To turn on the measurer press MEASURE The measurer turns itself off if no key is pressed within about 4 minutes or press MEASURE for 3 seconds to turn it off TAKING A MEASURE...

Page 2: ...h uneven surfaces If you are not sure if a measurement is correct move slightly to one side then measure the distance again If the surface of a wall you are measuring is not solid and flat of if you are measuring in a narrow corridor you might receive a false reading If this happens use a solid surface to measure or move to the center of the corridor To measure a distance longer than 60 feet 18 28...

Page 3: ...ULATING AREA Follow these steps to find the area of any two stored measurements 1 Measure the width and length of a room and store the measurements in M1 and M2 see Saving a Measurement Press AREA M1 and M2 the area calculation appear ADDING SUBTRACTING STORED MEASUREMENTS 1 Measure any two dimensions of a room and store the measurements in memory locations 1 and 2 see Saving a Measurement 2 Press...

Page 4: ...ypical individual units might vary Specifications are subject to change and improvement without notice Caution The laser emitted from the unit is visible laser of 650nm wavelength Don t stare into the laser beam and also don t shoot laser beam to any other s eyes Class Ⅱ laser product Output 1mw Notes The product has passed EN60825 1 1994 A11 1996 21CFR 1040 10 1040 11 Corresponding label is affix...