Vestil Manufacturing Corporation (“Vestil”) warrants this product to be free of defects in material and workmanship 

during the warranty period. Our warranty obligation is

 

to provide a replacement for a defective, original part covered 

by the warranty after we receive a proper request from the Warrantee (you) for warranty service. 

 

Who may request service? 

Only a warrantee may request service. You are a warrantee if you purchased the product from Vestil or from an 

authorized distributor AND Vestil has been fully paid. 

 

Definition of “original part”? 

An original part is a part used to make the product as shipped to the Warrantee. 

 

What is a “proper request”? 

A request for warranty service is proper if Vestil receives: 1) a photocopy of the Customer Invoice that displays the 

shipping date; AND 2) a written request for warranty service including your name and phone number.  Send requests 

by one of the following methods: 

 

     US Mail   

 

 

 

               Fax   

 

 

Email 

       Vestil Manufacturing Corporation   

        (260) 665-1339 

 

    

[email protected]

  

       2999 North Wayne Street, PO Box 507 

               Phone                 

Enter “Warranty service request” 

       Angola, IN 46703   

 

 

        (260) 665-7586 

      

in the subject field. 

 

In the written request, list the parts believed to be defective and include the address where replacements should be 

delivered.  After Vestil receives your request for warranty service, an authorized representative will contact you to 

determine whether your claim is covered by the warranty.  Before providing warranty service, Vestil will require you to 

send the entire product, or just the defective part (or parts), to its facility in Angola, IN. 

 

What is covered under the warranty?

 

The warranty covers defects in the following original, dynamic parts: motors, hydraulic pumps, motor controllers, 

and cylinders.  It also covers defects in original parts that wear under normal usage conditions (“wearing parts”), such 

as bearings, hoses, wheels, seals, brushes, and batteries. 

 

How long is the warranty period?

 

The warranty period for original dynamic components is 1 year. For wearing parts, the warranty period is 90 days. 

Both warranty periods begin on the date Vestil ships the product to the Warrantee.  If the product was purchased from 

an authorized distributor, the periods begin when the distributor ships the product.  Vestil may, at its sole discretion, 

extend a warranty period for products shipped from authorized distributors by up to 30 days to account for shipping 

time. 

 

 

If a defective part is covered by the warranty, what will Vestil do to correct the problem?

 

Vestil will provide an appropriate replacement for any 

covered

  part.    An authorized representative of Vestil  will 

contact you to discuss your claim. 

 

What is not covered by the warranty? 

The Warrantee (you) is responsible for paying labor costs and freight costs to return the product to Vestil for 

warranty service.

 

 

Events that automatically void this Limited Warranty. 

  Misuse; 

  Negligent assembly, installation, operation or repair; 

  Installation/use in corrosive environments; 

  Inadequate or improper maintenance; 

  Damage sustained during shipping; 

  Collisions or other accidents that damage the product; 

  Unauthorized modifications: Do not modify the product IN ANY WAY without first receiving written authorization 

from Vestil.   

 

Do any other warranties apply to the product? 

Vestil Manufacturing Corp.

 

makes no other express warranties. All implied warranties are disclaimed to the extent 

allowed by law. Any implied warranty not disclaimed is limited in scope to the terms of this Limited Warranty. Vestil 

makes no warranty or representation that this product complies with any state or local design, performance, or safety 

code or standard. Noncompliance with any such code or standard is not a defect in material or workmanship.  

 

 

Summary of Contents for ZLTT Series

Page 1: ...ur Technical Service and Parts Department at 260 665 7586 The department can also be contacted online at http www vestilmfg com parts_info htm Table of Contents Specifications 2 Signal Words 2 Hazards...

Page 2: ...1 6cm 44 111 8cm 48 121 9cm 83 3 4 212 7cm 69 1 4 175 9cm 4 000 lb 1 818 2 kg 2630 lb 1195 5 kg ZLTT 5272 2 48 71 1 2 181 6cm 52 132 1cm 48 121 9cm 83 3 4 212 7cm 77 1 4 196 2cm 2 000 lb 909 1 kg 2756...

Page 3: ...he machine to support people This table is designed only for material handling Always watch the tabletop carefully as well as the load container while raising and lowering it This crane is designed fo...

Page 4: ...10 102 Weldment leg assembly left 1 20 64135 Pin roll 3 16 x1 1 4 4 7 99 021 906 001 99 021 901 001 Cylinder hydraulic ram style ZLTT 4452 2 36 2 1 2 x10 ZLTT 4452 4 36 3 x10 2 21 15 112 002 Pin cylin...

Page 5: ...0 102 Weldment leg assembly left 1 20 64135 Pin roll 3 16 x1 1 4 4 7 99 021 906 001 99 021 901 001 Cylinder hydraulic ram style ZLTT 5252 2 48 2 1 2 x10 ZLTT 5252 4 36 3 x 10 2 21 15 112 002 Pin cylin...

Page 6: ...ment leg assembly left 1 20 64135 Pin roll 3 16 x1 1 4 4 7 99 021 906 001 99 021 901 001 Cylinder hydraulic ram style ZLTT 4472 2 48 2 1 2 x10 ZLTT 4472 4 48 3 x 10 2 21 15 112 002 Pin cylinder bracke...

Page 7: ...ment leg assembly left 1 20 64135 Pin roll 3 16 x1 1 4 4 7 99 021 906 001 99 021 901 001 Cylinder hydraulic ram style ZLTT 5272 2 48 2 1 2 x10 ZLTT 5272 4 48 3 x 10 2 21 15 112 002 Pin cylinder bracke...

Page 8: ...0VAC Single Phase Electric Circuit Diagram 04124019 Rev D NOTE Overcurrent short circuit protection and disconnect must be provided by the end user Control relay base layout top view Control relay bas...

Page 9: ...he necessary length of the anchor bolts should be determined by the building engineer Drill 1 2 holes into the concrete at the location of each bracket hole to the necessary depth for your anchor bolt...

Page 10: ...opens a path for fluid to flow back to the reservoir if fluid pressure exceeds 3 000psi The relief valve is a safety feature designed to prevent damage to the hydraulic system that would otherwise be...

Page 11: ...ut pressing either of the necessary control buttons then the corresponding lowering cartridge valve needs to be cleaned Remove inspect and clean the lowering cartridge valve If the tabletop un tilts o...

Page 12: ...levated table Describe the motion of the table as it rises as well as how it sounds Tilt the table Take more photographs and again describe the motion and sounds heard as the power unit operates Un ti...

Page 13: ...oil of viscosity grade 150 SUS at 100 F ISO 32 at 40 C such as AW 32 or HO 150 or a non synthetic transmission fluid Synthetic transmission fluid can be used but only after slushing the hydraulic sys...

Page 14: ...breakers and overloads to determine cause u Test all parts of circuit with multi meter v Walk around the table and look for items material etc interfering with table movement w Check solenoid with mu...

Page 15: ...aulic pumps motor controllers and cylinders It also covers defects in original parts that wear under normal usage conditions wearing parts such as bearings hoses wheels seals brushes and batteries How...