5-5
FLANGE GASKET
Sealing and electrical insulation between tank flange and flange of the heating element is provided by a gasket. In
cases where flange is removed, for example, when thermostat drum scale is cleaned, it must afterwards be replaced.
5-6
THERMOSTAT
Mechanical thermostat is used to set water temperature in desired level. Thermostat is mounted on front display
panel. For the thermostat to detect water temperature, it is placed in the steel pipe in capillary pipe thermocouple
heating coil flange. Thermocouple must be installed in the steel pipe such a way that it is secured to the bottom part.
Signal lamp is lit red while water is heated to temperature that thermostat is set. Signal lamp lights up green when
water reaches the desired temperature.