![VESTEL TRV 50 Service Manual Download Page 24](http://html.mh-extra.com/html/vestel/trv-50/trv-50_service-manual_1009494024.webp)
VESTEL WATER HEATER SERVICE MANUAL
VESTEL BEYAZ EŞYA A.Ş. (Air Conditioning Quality Assurance Department)
Page
23
WATER HEATER NOT WORKING
Turn on V-automate and measure
the voltage. Is there power supply in
bath stove?
No
Yes
V-automate is tripped or broken. Install
again, and replace if it does not work.
Check supply cable. Is it defective?
Yes
Replace supply
cable.
No
Is limit thermostat tripped?
Yes
Cool the water in the drum
and reinstall limit thermostat.
No
No
Check temperature
thermostat. Is output
provided to heating coil?
Yes
Replace thermostat
Check the
heating coil and
replace if
defective.
Check bath stove cable harness. Is
there burning, tearing or lack of
contact?
Yes
Replace cable
harness.
No