L
N
PE
L1
L2
N
PE
230V, 2N
S
1
2
3
4
5
S
230V
1
2
3
4
5
Before proceeding with the electical connection verify that:
The current carrying capacity of the system and the socket is adequate for the
maximum power rating of the hob.
The voltage indicated on the rating label is the same as the supply voltage.
Do not use for connection any reductions, adapters or shunts because they may
cause overheating.
Electrical connection of a built-in hob to an electric source is done with a cable
situated on the bottom of the built-in hob. Electrical installation of the residence and
the electric current socket must be earthed and conform with safety regulations. The
manufacturer declines responsibility should the appliance be installed without the
above mentioned conditions.
The appliance is provided for fixed connection to the power supply.
The connection of the appliance to an electrical source must be done by an qualified
technician (Connecting diagram given below).
A circuit breaker with a contact opening of at least 3 mm, rated 20A and delayed
functioning type must be installed inside the supply circuit.
·
·
·
·
·
·
·
·
Cooking hobs not provided with supply cord.
9
ELECTRICAL CONNECTION OF YOUR HOB
4