6
QSPEVDU
4 PRODUCT DATA
4.1 Product Data at Rated Condition
4.1.1 Duct Type
Model
Indoor unit
DGU09N
DGU12N
DHU18N
GU09N
GU12N
GU18N
Nominal
Capacity
Outdoor unit
Cooling
kW
2.6
3.5
5.0
Btu/h
8870
11940
17060
Heating
kW
2.85
3.6
5.7
Btu/h
9720
12280
19450
Power
Input
Cooling
kW
1.0
1.2
2.1
Heating
kW
0.97
1.8
EER/COP
W/W
2.60/2.94
2.38/3.17
Indoor Unit
DGU09N
DGU18N
-
Power Supply
Heat Exchange
-
Fan
-
Type
Drive
-
1.1
2.92/3.27
DGU12N
220-240V~/1 Ph/50HZ
Cross Fin Coil
Centrifugal fan
Direct
Driver
Motor Output
kW
0.03
0.037
0.06
Air Flow
m
3
/h
830/640/550
1130/960/830
1000/920/780
Pa
25
25
Ext. Static Pressure
Sound Pressure Level(H/M/L)
dB(A)
37/36/34
42/40/38
Air Filter
-
mm
ijî
ijî
Drain Piping
Dimensions (W×D×H)
mm
913×680×220
998×753×273
1012×736×266
1123×798×323
(Outline/Package)
Weight(Net/Gross)
kg
24/29
34/41
Outdoor Unit
GU09N
GU18N
-
Power Supply
Heat Exchange
-
Fan
Type
-
25
40/38/36
Standard washable synthetic
ijî
913×680×220/
998×753×273
25/30
GU12N
220-240V~/1Ph/50HZ
Cross
Fin Coil
Axial fan
Motor Output
kW
0.03
0.048
0.048
Fan Motor Speed
rpm
850
900
900
Compressor
Type
-
ROTARY
Motor Output
kW
0.922
1.185
1.9
Refrigerant
Type
-
R410A
Control
-
Capillary Tube
kg
1.1
1.0
1.5
Charge
Dimensions (W×D× H)
mm
820×320×540/
873×363×605
820×320×540/
873×363×605
820×320×540/
873×363×605
(Outline/Package)
Weight(Net/Gross)
kg
32/37
32/37
40/45
Piping
Connections
mm
6.35
6.35
6.35
mm
9.52
12.7
12.7
m
20
20
20
Liquid
Gas
Max. Length
Max. Height Difference
m
15
15
15
Summary of Contents for CGU12N
Page 1: ...INSTRUKCJA SERWISOWA KLIMATYZATORÓW CGU FGU DGU T1 R410A 50Hz GC201109 I ...
Page 4: ...1 PRODUCT QSPEVDU ...
Page 26: ...23 CONTROL DPOUSPM ...
Page 27: ...24 QSPEVDU CONTROL 1 OPERATION FLOWCHART 1 1 Cooling Dry Operation ...
Page 28: ...25 QSPEVDU 1 2 Heating Operation ...
Page 43: ...40 INSTALLATION ...
Page 77: ...74 MAINTENANCE ...
Page 84: ...81 QSPEVDU Malfunction display E6 Communications Failure ...
Page 89: ...86 QSPEVDU 2 GU12N WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING ...
Page 90: ...87 QSPEVDU 3 GU18N WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING ...
Page 91: ...88 QSPEVDU 4 GU24N WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING ...
Page 92: ...89 QSPEVDU 5 GU30N WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING ...
Page 93: ...90 QSPEVDU 6 GU36N WITH FUNCTION OF LOW TEMP COOLING J WITHOUT FUNCTION OF LOW TEMP COOLING J ...
Page 94: ...91 QSPEVDU 7 GU36N3 WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING ...
Page 95: ...92 QSPEVDU 8 GU42N3 WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING ...
Page 98: ...95 QSPEVDU 3 2 3 Cassettle Type Model CGU09N CGU12N CGU18N CGU24N CGU30N CGU36N CGU42N CGU48N ...
Page 132: ...129 QSPEVDU 2 Model GU24N Exploded Views ...
Page 134: ...131 QSPEVDU 3 Model GU30N Exploded Views ...
Page 138: ...135 QSPEVDU 5 Model GU42N3 GU48N3 Exploded Views ...
Page 140: ...137 QSPEVDU 6 Model GU60N3 Exploded Views ...
Page 142: ...139 QSPEVDU 5 1 2 WITH FUNCTION OF LOW TEMP COOLING 1 Model GU09N GU12N GU18N Exploded Views ...
Page 145: ...142 QSPEVDU 2 Model GU24N Exploded Views ...
Page 147: ...144 QSPEVDU 3 Model GU30N Exploded Views ...
Page 149: ...146 QSPEVDU 4 Model GU36N GU36N3 Exploded Views ...
Page 151: ...148 QSPEVDU 5 Model GU42N3 GU48N3 GU60N3 Exploded Views ...
Page 154: ...151 QSPEVDU 5 2 Indoor Unit 5 2 1 Duct Type 1 Model DGU09N DGU12N DGU18N Exploded Views ...
Page 158: ...155 QSPEVDU 5 2 2 Cassette Type 1 Model CGU12N CGU18N Exploded Views ...
Page 160: ...157 QSPEVDU 2 Model CGU12N CGU30N CGU36N CGU42N CGU48N Exploded Views ...
Page 163: ...160 QSPEVDU 3 Model CGU30N Exploded Views ...
Page 177: ...Vidicon Ltd Commercial Air Conditioners R410A Systems ...