159
QSPEVDU
Exploded Views:
No.
Name of part
CGU42N
Product Code
ET020N0020
CGU48N
Product Code
ET020N0040
Part code
Quantity
Part code
Quantity
1
Tube Exit plate
01382715
1
01382715
1
2
Body Fixing Plate
01332701
4
01332701
4
3
Front Side Plate
01302713
1
01302713
1
4
Left Side Plate
01302711
1
01302711
1
5
Base Plate
01222701
1
01222701
1
6
Rear Side Plate
01302709
1
01302709
1
7
Motor Support
01702701
1
01702701
1
8
Motor
15709410
1
15709410
1
9
Centifugal Fan
10310101
1
10310101
1
10
Evaporator Linkage
01072732
1
01072732
1
11
Tube sensor
390001921G
1
390001921G
1
12
Evaporator Assy
01029405
1
01029505
1
13
Water Tray Assy
20182701
1
20182701
1
14
Electric Base Plate
01412721
1
01412721
1
15
Flow-guide Loop
10372722
1
10372722
1
16
Electric Box
20102701
1
01412721
1
17
Terminal Board
42010258
1
42010258
1
18
Transformer
43110226
1
43110226
1
19
Electric Box Cover I
20102702
1
20102702
1
20
Room sensor
390001911
1
390001911
1
21
Electric Box Cover II
20102703
1
20102703
1
22
Main PCB Z71351E
30227111
1
30227111
1
23
Capacitor CBB61
33010012
1
33010012
1
24
Evap Support
01072707
2
01072707
2
25
Fan Fixer
10312701
1
10312701
1
26
Water Pump
43130324
1
43130324
1
27
Water Level Switch
45010201
1
45010201
1
28
Pump Drainpipe
05230026
1
05230026
1
29
Right Side Plate
01302712
1
01302712
1
30
Pump Cover Plate
01252713
1
01252713
1
31
Display Board
30297301
1
30297301
1
Summary of Contents for CGU12N
Page 1: ...INSTRUKCJA SERWISOWA KLIMATYZATORÓW CGU FGU DGU T1 R410A 50Hz GC201109 I ...
Page 4: ...1 PRODUCT QSPEVDU ...
Page 26: ...23 CONTROL DPOUSPM ...
Page 27: ...24 QSPEVDU CONTROL 1 OPERATION FLOWCHART 1 1 Cooling Dry Operation ...
Page 28: ...25 QSPEVDU 1 2 Heating Operation ...
Page 43: ...40 INSTALLATION ...
Page 77: ...74 MAINTENANCE ...
Page 84: ...81 QSPEVDU Malfunction display E6 Communications Failure ...
Page 89: ...86 QSPEVDU 2 GU12N WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING ...
Page 90: ...87 QSPEVDU 3 GU18N WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING ...
Page 91: ...88 QSPEVDU 4 GU24N WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING ...
Page 92: ...89 QSPEVDU 5 GU30N WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING ...
Page 93: ...90 QSPEVDU 6 GU36N WITH FUNCTION OF LOW TEMP COOLING J WITHOUT FUNCTION OF LOW TEMP COOLING J ...
Page 94: ...91 QSPEVDU 7 GU36N3 WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING ...
Page 95: ...92 QSPEVDU 8 GU42N3 WITH FUNCTION OF LOW TEMP COOLING WITHOUT FUNCTION OF LOW TEMP COOLING ...
Page 98: ...95 QSPEVDU 3 2 3 Cassettle Type Model CGU09N CGU12N CGU18N CGU24N CGU30N CGU36N CGU42N CGU48N ...
Page 132: ...129 QSPEVDU 2 Model GU24N Exploded Views ...
Page 134: ...131 QSPEVDU 3 Model GU30N Exploded Views ...
Page 138: ...135 QSPEVDU 5 Model GU42N3 GU48N3 Exploded Views ...
Page 140: ...137 QSPEVDU 6 Model GU60N3 Exploded Views ...
Page 142: ...139 QSPEVDU 5 1 2 WITH FUNCTION OF LOW TEMP COOLING 1 Model GU09N GU12N GU18N Exploded Views ...
Page 145: ...142 QSPEVDU 2 Model GU24N Exploded Views ...
Page 147: ...144 QSPEVDU 3 Model GU30N Exploded Views ...
Page 149: ...146 QSPEVDU 4 Model GU36N GU36N3 Exploded Views ...
Page 151: ...148 QSPEVDU 5 Model GU42N3 GU48N3 GU60N3 Exploded Views ...
Page 154: ...151 QSPEVDU 5 2 Indoor Unit 5 2 1 Duct Type 1 Model DGU09N DGU12N DGU18N Exploded Views ...
Page 158: ...155 QSPEVDU 5 2 2 Cassette Type 1 Model CGU12N CGU18N Exploded Views ...
Page 160: ...157 QSPEVDU 2 Model CGU12N CGU30N CGU36N CGU42N CGU48N Exploded Views ...
Page 163: ...160 QSPEVDU 3 Model CGU30N Exploded Views ...
Page 177: ...Vidicon Ltd Commercial Air Conditioners R410A Systems ...