 Maintenance

 

Electrode Needle Cleaning/Replacement (cont.) 

CAUTION

 

  CLEANING 

If the discharge needle is dirty, it could lower the static erasing performance or cause 
dust to fly around. Be sure to clean the contaminated parts according to your service 
condition. 

When replacing the Electrode Needles 

If the static erasing performance does not recover even after cleaning the electrode needles,   
they may be worn out. 
Remove the front cover in the same way as for cleaning and replace it with a new one. 

Be careful not to stick yourself on the needles. 

 

WARNING

 

 PROHIBITED

 

If the electrode needles is broken or worn out, stop the operation and replace it with a 
new one. It can lead to an electric shock or injury. 

When cleaning the filter (Option) 

After being used for a long time with a filter available as option, dust adhered to the filter could lower 
ionizing performance or cause dust to fly around. Be sure to periodically clean or replace the filter.   
1) Before cleaning the filter, stop operation of the F120R-E, turn off power.   
2) Unplug the AC adapter or pull out the wires from input/output terminals. 
3) Take out the filter cover. 
4) Remove and clean the filter. Make sure the falter is completely dry before reuse. Installing the filter 
while still wet may damage the F120R-E. 
5) Wipe off the dust adhered on the filter cover with a cloth. Dust may also be on the outside and/or inside 
the filter cover, so use a dry and soft cloth to wipe dust off. 
6) Mount again the filter and the filter cover. 
 

CAUTION

 

  CLEANING 

If the filter is dirty, it could lower the static erasing performance or cause dust to fly 
around. Be sure to clean the contaminated parts according to your service condition. 

When replacing the filter 

In the case that the dust cannot be removed even after cleaning, replace it with a new one. 
Remove the filter cover with the same procedure as for cleaning and then replace the filter with a new 
one. 

Consumables 

Front cover with 

Electrode needles 

F120R-E 

Filter set: F-120FS

 

Filter: L-90F 

 

 

 

 

 

Summary of Contents for Stat Clean F-120R-E

Page 1: ...re reference Table of Contents For Your Safety Product Features Production Specifications External View Performance Installation Before Use Operation Maintenance Troubleshooting Storage Warranty Instruction Manual Read this instruction manual before use Keep it in a safe handy place for future reference P 14 P 15 P 15 P 16 P 17 P 17 P 18 P 19 P 21 P 23 P 23 P 24 ...

Page 2: ...places or anywhere it may be wet by water oil solvent or other liquid Contact with moisture can result in electric shock or breakdown PROHIBITED Do not use the F120R E for any other purpose than static erasing or dust removal PROHIBITED Do not use the F120R E with power supplies of ratings not specified in the specifications Inappropriate power supplies can result in fire and electric shock PROHIB...

Page 3: ...ns Ionizer Product Number F120R E Model F 120 Ion generation method High voltage AC corona discharge Output voltage AC 10 kV p p Input voltage DC 24 V 5 700 mA max Dimensions H198 W162 D69 5 mm including stand Weight 0 9 kg Fan speed 3 66 m3 min Max fan speed Blow speed 5 0 m s HI 4 4 m s MD 3 9 m s LO Noise emission 61 dBA max and straight airflow without filter measured at 1m actual measured val...

Page 4: ... temperature humidity 0 40 C 10 85 RH No dewing or freezing Cable length DC output cable approx 1 8 m AC input cable approx 1 8 m Weight 135 g Consumables Electrode Needle Unit F 120RCH The measurement values were obtained using the VESSEL measurement environment so errors could be induced depending on the operation environment External View F120R E ...

Page 5: ...ectric shock and static electricity removal troubles REMEMBER Install the F120R E securely The F120R E can be damaged or malfunction if it is dropped REMEMBER Install the F120R E based on environments stated below Adverse environments cause product deterioration and breakdown Humidity 35 65 RH No dewing Temperature 5 40 Humidity 50 angle airflow at HI fan speed They represent the central tendency ...

Page 6: ...nt screws located on the left and right sides of the stand Phillips screw M6 Securely tighten the adjustment screws after adjustment Keep objects from getting in between the F120R E and the target area Before installing the F120R E check the strength of supporting structure Please keep backside of the F120R E away from the object and keep away from the wall surface at least 100mm for the proper fu...

Page 7: ...e supplier for servicing to avoid accidents Operation Power Power is turned on by pressing the Power switch H V lamp and fan lamp light up in green and then the unit start the operation When you press the power switch again power is turned off Fan speed The fan s airflow volume can be adjusted in three steps LO MD HI Please adjust the air with the Airflow switch Variable louver The airflow directi...

Page 8: ...ts are adhered to the fan remove them switch on the power again and make sure that the lamp is off If the alarm lamp light in red again even though the causes are resolved contact the supplier for servicing to avoid accidents Immediately after turning on the power there is a moment that the fan lamp glows red This is not a malfunction When externally outputting the alarm signal The lights and othe...

Page 9: ...periodical cleaning 1 Be sure to turn the power switch off to stop the operation 2 Unplug the power supply adapter from the electrical outlet 3 Remove the screw that secures the front cover 4 Removing the front cover 5 Wipe it with a dry soft cloth Be careful not to stick yourself on the needles 6 Reinstall the front cover When cleaning the front cover CAUTION CLEANING A dirty front cover could lo...

Page 10: ...d Be sure to periodically clean or replace the filter 1 Before cleaning the filter stop operation of the F120R E turn off power 2 Unplug the AC adapter or pull out the wires from input output terminals 3 Take out the filter cover 4 Remove and clean the filter Make sure the falter is completely dry before reuse Installing the filter while still wet may damage the F120R E 5 Wipe off the dust adhered...

Page 11: ... following cases contact the supplier for servicing Do not service the F120R E by yourself to avoid accidents The power lamp does not light when the power switch is in the ON position Air is not blown when the airflow switch is turned When the F120R E is moved during operation sometimes airflow comes out or sometimes not The power cable is excessively hot The power supply adapter is excessively ho...

Page 12: ... accidents neglect misuse alterations operator error or failure to properly maintain clean or repair products LIMIT OF LIABILITY This electronic static eraser use high voltage corona discharge and should not be used in or near flammable or explosive environments In no event will VESSEL or any seller is responsible or liable for any injury loss or damage direct or consequential whether based in tor...

Reviews: