Vertiv
™
NetSure
™
-48 VDC Power System
System Application Guide
Spec. No: 582140001
Proprietary and Confidential © 2022 Vertiv Group Corp.
SAG582140001
Model No: 801
NLDB
, 801
NLEB
, 801
NL
-
B
Page 13
Revision T, September 28, 2022
2)
Order up to twenty-four (24) Rectifiers Modules per bay per
(380/480VAC Input).
3)
Order additional MCA customer alarm relay circuit card(s) as required per
, and optional MCA I/O circuit cards per
4)
Order a Battery Charge Temperature Compensation Probe as required per
Optional Battery Charge Temperature
Compensation Probe for Digital Compensation
in the
ACCESSORY DESCRIPTIONS
section.
5)
Order optional LMS Monitor and LMS options as required per
, and SAG586505000.
6)
Order “Power Bay DC Output” lugs as required per
Power Bay DC Output Cable Sizes and Lugs Selection
in the
ACCESSORY DESCRIPTIONS
section.
7)
Order “AC Input Ground” lugs as required per
AC Input Wire and Conduit Sizes, Branch Circuit Protection, and Lugs
in the
ACCESSORY DESCRIPTIONS
section.
8)
Order “Power Bay Frame Grounding” lugs as required per
Power Bay Frame Grounding Wire Sizes and Lugs Selection
the
ACCESSORY DESCRIPTIONS
section.
9)
If the system is to be connected to an existing system with an MCA, refer to List
List 12: Secondary Power Bay (2 AC Input Feeds)
Features
♦
Provides common equipment for one (1) Power Bay rated for up to 2400 amperes.
♦
Mounted in a 7'0"H x 24.375"W x 30"D seismic rated (Zone 4) box framework.
♦
Provides twenty-four (24) Rectifier Module mounting positions.
♦
Provides an AC input termination panel that accepts two (2) AC input branch circuits, one (1) per twelve (12) Rectifier
Module mounting positions. A 60A AC input circuit breaker rated for 65kA interrupting capacity is provided for each pair
of rectifier positions in the List B Bay. A 30A AC input circuit breaker rated for 22kA interrupting capacity is provided for
each pair of rectifier positions in the List A Bay.
♦
Includes a Router Assembly for bay communication to the MCA in the Primary Power Bay.
♦
Provides mounting for optional LMS Expansion CPU circuit card.
♦
Provides a seven-slot card cage for mounting MCA customer alarm relay circuit cards, MCA I/O circuit cards, and/or
optional LMS I/O circuit cards.
♦
MCA Network bay interconnect cable provided (Qty. 1 P/N 514642).
Ordering Notes
1)
(208VAC Input).
2)
Order up to twenty-four (24) Rectifiers Modules per bay per
3)
Order additional MCA customer alarm relay circuit card(s) as required per
, and optional MCA I/O circuit cards per
4)
Order optional LMS Expansion CPU circuit card and LMS options as required per
, and SAG586505000. Also
order additional LMS Network cables as required per
Replacement/Additional LMS Network Cables
5)
Order “Power Bay DC Output” lugs as required per
Power Bay DC Output Cable Sizes and Lugs Selection
in the
ACCESSORY DESCRIPTIONS
section.
6)
Order “AC Input” lugs as required per
AC Input (Dual AC Input Feeds) Wire and Conduit Sizes, Branch Circuit Protection,
and Lugs Selection
in the
ACCESSORY DESCRIPTIONS
section.
7)
Order “Power Bay Frame Grounding” lugs as required per
Power Bay Frame Grounding Wire Sizes and Lugs Selection
the
ACCESSORY DESCRIPTIONS
section.
8)
If a different length LMS and/or MCA Network cable is required, order per
Replacement/Additional LMS Network Cables
and/or
Replacement/Additional MCA Network Cables
. Refer to the Installation Instructions (Section 6016) for Network
cabling requirements.
9)
Side cover panels are not provided. When bays are placed next to each other, the side cover panels from the ‘inside’ side
of the Primary Power Bay are moved to the ‘outside’ side of the last Secondary Power Bay. In installations where a
Secondary Power Bay is placed by itself, order (4) P/N 535092 side cover panels.