background image

Liebert®

IntelliSlot™ Unity™ Card

Installer/User Guide

Summary of Contents for Liebert IntelliSlot Unity Card

Page 1: ...Liebert IntelliSlot Unity Card Installer User Guide ...

Page 2: ...and disclaims all liability for damages resulting from use of this information or for any errors or omissions Refer to other local practices or building codes as applicable for the correct methods tools and materials to be used in performing procedures not specifically described in this document The products covered by this instruction manual are manufactured and or sold by Vertiv This document is...

Page 3: ...Cloud Client for Liebert Mini Mate 18 4 1 Typical Configuration for Cloud client Support Prerequisites 18 4 2 Registering with the Cloud Service Administration Portal to Allow Mobile app Users Access 19 5 Unity Card Web page Layout 21 5 1 Web Page Sections 21 5 2 Help Text 23 5 3 Managed Device Tab Menus 23 5 4 Communications Tab Menu 23 5 5 Sensor Tab Menu 26 5 5 1 Sensor tab Summary Page 27 5 5 ...

Page 4: ...et Folder 53 6 5 2 Modbus Folder 54 6 5 3 SNMP Folder 56 6 5 4 YDN23 Folder 59 6 6 Status Folder 59 6 7 Support Folder 60 6 7 1 Active Networking Folder 61 6 7 2 Firmware Update Folder 62 6 7 3 Configuration Export Import Folder 64 6 7 4 Manually Restarting the Card 67 6 7 5 Manually Resetting to Factory Defaults 67 Vertiv Liebert IntelliSlot Unity Card Installer User Guide iv ...

Page 5: ... Unity LIFE cards Each card employs the Velocity Protocol to monitor and manage a wide range of operating parameters alarms and notifications The card communicates with Building Management Systems and Network Management Systems via BACnet Modbus SNMP LIFE Remote Services and YDN23 protocols Figure 1 1 IS Unity DP Card Features ITEM DESCRIPTION 1 RJ 45 Ethernet port 2 Micro USB port 3 Reset button ...

Page 6: ...10 Liebert SN modular and integrated sensors Available sensor types include temperature humidity door closure contact closure and leak detection Sensor tab menus permit configuring sensors and putting them in user configured order for easier checking of high priority conditions Sensor data is available via SNMP and the Web user interface See Sensor Tab Menu on page 26 Vertiv Liebert IntelliSlot Un...

Page 7: ...on Can cause equipment damage Only a qualified service professional should install these products We recommend that a Vertiv technician perform the installation in large UPS system Contact Vertiv at https www vertivco com en us support NOTICE Risk of duplicate node IDs if two or more Liebert IntelliSlot cards are installed Can cause network conflicts An internal networking conflict will occur with...

Page 8: ...1 1 on page 1 Computer Automated Private IP addressing APIPA is normally enabled by default on computers running the Microsoft Windows operating system and will assign an Autoconfiguration IPv4 address when a DHCP server is not detected NOTE This IP autoconfiguration process can take 1 to 3 minutes If necessary use the Windows Command Prompt to verify the computer s IP address settings Press the W...

Page 9: ... assigned by the DHCP server use a computer with a direct Ethernet connection to the card and the Autoconfiguration IPv4 Address convention described in Connecting Directly to Computer for Configuration on the previous page to access the card s Web page To see the card s last DHCP assigned IP address 1 Click the Communications tab then on the left side menu select Support Active Networking 2 Check...

Page 10: ...ire is exposed for connection about 1 4 in 6 mm NOTE No bare wire should be exposed when the connection is completed 3 Position the adapter so the side with the positive and negative marks is face up The small markings are on the same side as the screw heads as shown Figure 2 2 Adapter terminal block marks face up ITEM DESCRIPTION 1 Screws 2 Wires 4 Loosen the screw to the positive terminal and in...

Page 11: ...are both Liebert case sensitive d Click to check enabled e Enter the assigned IP address along with the rest of the required networking information Contact your system administrator if necessary 3 Click Save to confirm the changes or Cancel to discard them The changes take effect after the card is restarted 2 4 Installing Multiple Cards in a System More than one Liebert IntelliSlot card may be ins...

Page 12: ...e equipment and verified that the settings support the desired operational functionality without adding unnecessary or unauthorized access to critical infrastructure equipment A reference to the proper section in this document is provided for configuring each item ITEM DESCRIPTION REFERENCE Accounts Passwords Change the admin and user account names and passwords immediatelyto eliminate default cre...

Page 13: ...ame subnet as the device or limited to only those from systems on aTrusted IP Address List Enable Modbus Protocolon page 11 SNMP Version Settings Enable disable the desired SNMP version s Consider using SNMPv3 with user authentication and encryption Configure SNMP Settings on page 15 SNMP Access Table Settings For each SNMPv1 v2c Access table entry set the SNMP Access Type to Read Only to prevent ...

Page 14: ...FIED Web HTTP TCP 80 Yes Yes HTTPS TCP 443 Yes Yes DNS TCP UDP 53 Yes No NTP TCP UDP 123 Yes No SMTP TCP 25 Yes Yes SSHv2 TCP UDP 22 Yes No Telnet TCP 23 Yes No SNMP UDP 161 162 Yes Only trap port 162 may be changed Modbus TCP TCP 502 Yes Yes BACnet IP UDP 47808 Yes Yes Velocity Protocol UDP 47808 Yes No LIFE TCP 80 Yes Yes Table 2 2 Ports used by the Unity card Details for configuration of all op...

Page 15: ... device to proceed 3 1 Enable Protocols Protocols may be enabled after a card is installed and configured for basic network connectivity After a protocol is enabled it must be configured which requires opening the folder for the desired protocol Communications tab Protocols protocol to configure To enable two communication protocols 1 On the Communications tab select Protocols 2 Click Edit and ent...

Page 16: ... Network Access Type 5 Enter the Maximum Client Connection Count 6 Click Save to confirm the changes or Cancel to discard them 7 Restart the card a On the Communications tab click Support b Click Enable c Click Restart Configure Modbus RTU 1 On the Communications tab select Protocols Modbus Modbus RTU 2 Click Edit and enter a user name and password if necessary 3 Enter the Node ID and the Baud Rat...

Page 17: ...dministrator or building management system administrator if you are uncertain about the settings 1 On the Communications tab select Protocols BACnet BACnet IP 2 Click Edit and enter a user name and password if necessary 3 Enter the BACnetIP Port Number If the Unity card is on a different subnet a possibility when the monitored units are part of a Liebert SiteScan network or other third party monit...

Page 18: ...nged 1 On the Communications tab select Protocols SNMP 2 Click Edit and enter a user name and password if necessary 3 To enable Authentication Traps click to check the box 4 To change the Heartbeat Trap Interval choose a time from the drop down list or choose Disabled to prevent any heartbeat traps from being sent The interval times offered are 5 minutes 30 minutes or 1 4 8 12 or 24 hours 5 For ea...

Page 19: ... ID may be selected the access settings for SNMPv1 v2c are separate from SNMPv1 trap settings Select SNMPv3 Engine ID Format By default the Engine ID is automatically generated using the MAC address Optionally you can select a text based ID instead 1 On the Communications tab select Protocols SNMP 2 Click Edit and enter a user name and password if necessary 3 Edit the settings Refer to SNMP Folder...

Page 20: ...ion and set the permissions appropriate to the user For descriptions of the settings and options see SNMPv3 User Folder on page 57 4 Click Save to confirm the changes or Cancel to discard them 5 Repeat steps 1 through 4 for additional users 6 Restart the card to activate the changes a On the Communications tab click Support b Click Enable c Click Restart Configure SNMPv1 Trap Settings 1 On the Com...

Page 21: ... the Communications tab click Support b Click Enable c Click Restart 3 2 Download Protocol Mappings The Unity Card permits downloading files that list information available from a managed device for each enabled protocol The listings identify the data available from the device and how that data will be represented or mapped into a particular protocol NOTE The Liebert SN sensors are not supported v...

Page 22: ...URL The Cloud Service URL is typically https icomcms com DNS must be configured and working appropriately because it is used to access the Cloud Service The Unity card must have a System Name that is unique to the Organization The Unity card System Name maps to the Manager Name in the Cloud Service The managed device must be a Mini Mate Thermal Management System Otherwise the Cloud Client folder i...

Page 23: ...the Unity card 2 On the connected computer open a Web browser and enter the card s default address 169 254 24 7 in the address bar The Unity web user interface opens 3 Configure the System Name before attempting to register the Mini Mate unit On the Unity web UI click the Communications tab In the Communications pane on the left hand side select Configuration System Click Edit and enter the defaul...

Page 24: ...he address for the cloud service administration portal through which mobile app users are managed 10 Click Save 11 Restart the card for the changes to take effect Communications pane on the left hand side select Support In the Commands section click Enable and enter the default Username and Password which is Liebert case sensitive for both Click Restart Card The device is registered with the Cloud...

Page 25: ...roubleshooting problems You can name the equipment enter a location set up email and text alerts and change equipment settings NOTE The Edit button is grayed out if the settings on a menu cannot be changed 5 1 Web Page Sections Each Unit card has a Web page user interface Web UI with the following areas see Figure 4 1 below Identification panel Status panel Tab menu panel Detail area Figure 4 1 We...

Page 26: ... Communications tab displays information about the Unity card such as the overallevent status of the equipment and communication interface logs of third party information communication settings third party protocolsettings and system status Refer to Communications Tab Menu on the facing page for details 4 Details areadisplays detailed information about the device based on the menu selection made i...

Page 27: ...r example menus shown by a Unity card installed in a UPS differ from menus shown by a card installed in Thermal Management equipment Selected menu items also display detailed information based on the equipment in which the card is installed Power information is displayed in the Managed Device tab for a UPS while environmental information is displayed for a thermal management unit 5 4 Communication...

Page 28: ...s Remote Authentication Network Web Server LIFE Remote Services Velocity Protocol Messaging Displays information about the system setup access network connections Velocity Protocolsettings and whether emailand SMS messaging are enabled Configuration Folder on page 30 Protocols Modbus BACnet SNMP YDN23 Lists information and settings related to available third partyprotocols employed to monitor equi...

Page 29: ...irmware Version Agent Boot Firmware Label Agent SerialNumber Agent Manufacture Date Agent Hardware Version GDD Version FDM Version Product Sequence ID Restart Card Reset Card to Factory Defaults see NOTEbelow Generate and download diagnostic file Firmware Update Active Networking Shows information needed for maintenance or troubleshooting and shortcuts to reboot the card reset the Unity card to it...

Page 30: ... for sensor identification location 2 Actualsensor reading values 3 Graphs indicate sensor readings in relationship to thresholds 4 Icons indicate sensor status readings for example cable fault or door open closed depending on sensor function 5 Sensor details datafor sensor selected in the summarylist 6 Sensor settings editable data configuration for sensor selected in the summarylist Vertiv Liebe...

Page 31: ...Clicking the Acknowledge button clears the list The Acknowledge button on this page has the same behavior as the Acknowledge button on the Sensor Server page Sensor Order Displays alist of sensors and allows setting the order in which the sensors are displayed on the Summarypage Table 4 3 Sensor tab menu folders 5 5 1 Sensor tab Summary Page The Sensor tab Summary Page shows the status of all inst...

Page 32: ...r the sensors include the current state or reading event status and whether the reading is above or below the threshold established in the Settings pane 5 5 3 Changing Sensor Order Sensors are listed in the order they are installed You can change the order to put sensors deemed more important at the top of the list To change the order of the sensor list 1 On the Sensor tab click Sensor Order 2 Cli...

Page 33: ...t and communication interface It presents logs of third party information communication settings third party protocol settings and system status information The Communications folders are Active Events Folder below Downloads Folder below Configuration Folder on the next page Protocols Folder on page 53 Status Folder on page 59 Support Folder on page 60 6 2 Active Events Folder The Active Events fo...

Page 34: ...played which is Celsius by default To edit the information displayed 1 Click Edit and enter a user name and password if necessary 2 Make the changes and click Save Time Service Settings The System subfolder contains the Time Service folder Each setting offers a menu of choices or an enable disable check box Time Service setting options External Time Source The external source to use for time synch...

Page 35: ...re case sensitive The Authorization access type for LocalUser 1 is Administrator Be sure that you always have one administrator user so you can access and modify configuration and other settings Table 5 1 User access Levels IMPORTANT Record user names and passwords and save them in a secure place where they can be found if forgotten A lost password cannot be retrieved from the IS UNITY card If the...

Page 36: ...t serves as a password between the client and the server Timeout Time in milliseconds between authentication retries Range 0 to 65535 Retries Number of times to attempt contact before trying a different server Server Configuration Requirements for RADIUS Authentication The value for Filter Id must be unity_group unityadmin or unity_group unityuser The attributes are in a config file or a GUI inter...

Page 37: ...e SSL mode Database UserName Bind Distinguished Name the service account used to access the LDAP server Database Password Password for the service account that accesses the LDAP server Login Attributes Account attribute that authenticates the user credentials for example CN Server Configuration Requirements for LDAP Authentication The value for info must be unity_group unityadmin or unity_group un...

Page 38: ...onsidered for specifying for a user The Info attribute already exists in the LDAP schema but it is not assigned to anything in the default schema To add the Info attribute on a brand new OpenLDAP installation Before starting OpenLDAP refer to the following to edit the nis ldif file Original posixAccount object schema olcObjectClasses 1 3 6 1 1 1 2 0 NAME posixAccount DESC Abstraction of an account...

Page 39: ...address of the primary TACACS server Secondary Authentication Server IP address of the secondary TACACS server Secret The shared secret that serves as a password between the client and the server Timeout Time in milliseconds between authentication retries Range 0 to 65535 Retries Number of times to attempt contact before trying a different server Version Minor version 6 Editing the Unity Card Conf...

Page 40: ... unityuser string in the raccess field user tacacsAdmin service raccess unity_group unityuser The attributes are in a config file or a GUI interface depend on the authentication server implementation The unity_group unityuser can be used in the same manner as unity_group unityadmin The unity_group unityadmin and unity_group unityuser string must be terminated with a semicolon Vertiv Liebert Intell...

Page 41: ...em administrator for the proper settings Hostname Identifies the network node Default UNITY serial_number_of_card Domain Name Suffix List Listing of domain name suffixes for resolution of host names If it requires changing contact the system administrator for the proper setting Telnet Server Enables Disables telnet access to the card to prevent unauthorized changes The default setting disables tel...

Page 42: ...interface Subnet Mask Network mask for the interface which divides a network into manageable segments Default Gateway IP address of the gateway for network traffic destined for other networks or subnets DNS Server Address Source Source of DNS server identification None Automatic Configured Primary DNS Server Network address of the primary DNS server Secondary DNS Server Network address of the seco...

Page 43: ...o the last query Example gxtwebdemo liebert com resolved to 126 4 203 251 Type of Query Type of DNS query Hostname IP Address Query Value Value for the domain name server DNS to resolve Example gxtwebdemo liebert com 6 4 5 Web Server Folder The Web Server Settings permits making some security settings such as HTTP or HTTPS and password enabling Web Server Settings Web Server Protocol Select the op...

Page 44: ...For additional information see Connecting Directly to Computer for Configuration on page 4 NOTE When Remote Write Access is disabled an indicator is displayed in the upper right corner of the web page as a reminder shown in the following figure NOTE Only disable remote write access if you are absolutely sure that you do not need to administer the managed device or the Unity card through a remote w...

Page 45: ...use of SSL certificates see http httpd apache org docs 2 4 mod mod_ssl html sslcertificatefile Generate Self Signed SSL Certificate Generates and installs a new self signed certificate based on the mode selected for Generate Self Signed SSL Certificate Mode See Generating a Self signed SSL Certificate on page 43 Certificate Settings Generate Self Signed SSL Certificate Mode Method used to generate...

Page 46: ...ion identified as the owner of the generated certificate Email Address Email address of the contact within the organization identified as owner of the generated certificate Uploading SSL Certificate PEM Files 1 On the Communications tab select Configuration Web Server Certificate 2 In Commands click Enable then click Upload next to Upload SSL Certificate PEM Files The upload dialog opens See the f...

Page 47: ... settings that affect use of the Vertiv LIFE Technology a remote monitoring and diagnostic service for Vertiv units The LIFE settings are for use by trained Vertiv personnel only and require no user changes The following tables provide reference information about the LIFE settings Settings in this folder are managed by Vertiv A service contract is required For support contact Vertiv Technical Supp...

Page 48: ...urs CallTrials Number The number of attempts to retry acallafter it fails before rescheduling the call Table 5 2 LIFE Status Settings continued SETTINGS DESCRIPTION Primary Mains Restored SMS Send SMS when Primary Mains are restored Primary Mains Restored SMS Value Value sent viaSMS when Primary Mains are restored Primary Mains Failure SMS Send SMS when Primary Mains fail Primary Mains Failure SMS...

Page 49: ...Serial Number Override is enabled Reset Remote Services Config Resets configuration of the remote service back to factory defaults NOTE Does not reset the communication card configuration Remote Service Enables Disables remote servcie connection Device Data Sampling Enables Disables data sampling of the device Device Serial Number Serial number used when Device Serial Number Override is enabled De...

Page 50: ...gth of time to attempt reconnection in the event of a communication failure Range 30 to 600 seconds Proxy Enable Enables use of remote service platform URL to connect with a proxy server Proxy Authentication Enables authentication of the proxy server Proxy Address IP or URL address of the proxy server Proxy IP Port Number Port number of the proxy server Range 1 to 65535 Proxy User Name User name o...

Page 51: ...vice s communication with the card 6 4 8 Velocity Protocol Folder Velocity Protocol contains four sub folders Managed Device MSTP Ethernet and Internal Velocity is the input protocol from a managed monitored system NOTE With the exception of changing the node ID when multiple cards are used or when disabling Velocity Protocol IP access the settings in the Velocity Protocol sub folders should not b...

Page 52: ...company com Email To Address Email address of the recipient Multiple email addresses are separated by a semicolon Email Subject Type Subject of the email This value will default to the event description unless customized by entering Custom Subject Text Custom Subject Text The editable subject of the message Defaults to event description if nothing is entered SMTP Server Address Fully qualified dom...

Page 53: ...MP event description will be included in outgoing messages Include Name in Message If checked the agent card Name will be included in outgoing messages Include Contact in Message If checked the agent card Contact will be included in outgoing messages Include Location in Message If checked the agent card Location will be included in outgoing messages Include Description in Message If checked the ag...

Page 54: ...rt Default 25 SMTP Connection SMTP server connection type Determines the capabilities of the SMTP server Options are Clear Do not use encryption SSL TLS Encryption using SSL TLS connection STARTTLS SSL TLS encryption initiated using STARTTLS SMTP Authentication Enable or disable SMS SMTP authentication An SMS account must be provided for the SMTP service provider to authenticate NOTE Some messagin...

Page 55: ... messages Include Web Link in Message If checked a Web link to the agent card and Web Server listening port number will be included in outgoing messages Enable Event Consolidation If checked multiple events will be sent per outgoing message Consolidation Time Limit If Event Consolidation is enabled a message will be sent when Consolidation Time Limit in seconds has passed since the first buffered ...

Page 56: ...ee System Folder on page 30 to configure the System Name and other device specific information NOTE The System Name must be configured before registering the unit with the cloud client Token Unique identifier provided by the cloud service that confirms registration If the unit is not registered the field displays Client Not Registered Cloud Client Settings options Cloud Client Enable Enables Disab...

Page 57: ...the next page BACnet MSTP Folder on the next page Modbus see Modbus TCP Folder on page 55 Modbus RTU Folder on page 55 SNMP see SNMPv3 User Folder on page 57 SNMPv1 Trap Folder on page 58 SNMPv1 v2c Access Folder on page 59 YDN23 see YDN23 Folder on page 59 6 5 1 BACnet Folder BACnet Settings Managed Device Write Access Enable or Disable the BACnet server to write to the managed device BACnet Inte...

Page 58: ... BACnet MSTP Settings Node ID The BACnet server s MS TP node ID MAC Must be unique for each node on the communication bus Data Rate The BACnet MSTP communication rate bits per second Max Master Address The maximum node ID MAC in use on the MS TP network Max Info Frames Maximum number of information frames this node may send before it must pass the token 6 5 2 Modbus Folder Modbus Settings Managed ...

Page 59: ...rusted IP List Port The TCP port used by the Modbus Server to listen for and respond to Modbus protocol requests Default 502 Maximum Client Connection Count Maximum number of simultaneous connections allowed Range 1 to 5 Modbus RTU Folder Modbus RTU Settings Node ID Modbus Server ID for the interface obtain from network administrator Must be unique for each node on the communication bus Baud Rate ...

Page 60: ...and 24 hours RFC 1628 MIB Enable or Disable support for retrieval of data from the RFC 1628 MIB objects RFC 1628 MIB Traps Enable or Disable support for sending RFC 1628 traps The RFC 1628 MIB must be enabled for RFC 1628 traps to operate These traps apply only to UPS systems Liebert Global Products LGP MIB Enable or Disable support for getting and setting data using the Liebert Global Products MI...

Page 61: ...a user such as SNMPv3 User 1 To display the settings click on any of the SNMPv3 User links After making any changes click Save to make the changes effective SNMPv3 User Settings SNMPv3 User Enable Select to enable read write or sending notifications with the user s credentials SNMPv3 Username The User name the authentication and privacy settings apply to This string can be composed of printable ch...

Page 62: ...same information in this screen as that displayed when folder or link for a specific user is selected SNMPv1 Trap Folder This page contains settings for network hosts that receive SNMPv1 traps Up to 20 trap recipients may be enabled and configured Like the SNMPv3 pages the settings for each target may be reached by clicking the links in the Detail portion of the page or by clicking the folders for...

Page 63: ...pe SNMPv1 v2C access type Read Only or Read Write SNMP Access Community String String identifying a secret to allow read only or write only access The default is read only acciess public case sensitive Write only access private case sensitive 6 5 4 YDN23 Folder The YDN23 protocol supported is based on the YD T 1363 specification using an RS 485 network connection YDN23 Protocol settings Managed De...

Page 64: ...higher Agent App Firmware Label The card s firmware label Agent Boot Firmware Version The card s Boot firmware version Agent Boot Firmware Label The card s boot firmware label Agent Serial Number The card s serial number Agent Manufacture Date The card s manufacture date Agent Hardware Version The card s hardware version GDD Version The card s GDD version current when the card s firmware was insta...

Page 65: ...ress Ethernet MAC Address for the Liebert IntelliSlot card IPv4 Address Presently used IPv4 network address IPv4 Default Gateway Presently used IPv4 network address of the gateway for network traffic destined for other networks or subnets Primary DNS Presently used IPv4 Primary DNS Secondary DNS Presently used IPv4 Secondary DNS Last DHCP BOOTP Address Last known IPv4 address assigned by DHCP Last...

Page 66: ...rnate image The folder supports updating the firmware of the Unity card or reverting to a previous version If the firmware has not been updated then the previous version configuration is not available to revert NOTE If downgrading firmware to a previous version a reset to factory defaults occurs if there are feature in the current version that are not present in the older version However if downgr...

Page 67: ... to a computer with an Ethernet cable and open a web browser see Connecting Directly to Computer for Configuration on page 4 The card has an Ethernet RJ 45 connector on the front see Figure 1 1 on page 1 When directly connected the card and computer automatically negotiate communications which takes about 1 minute When communication is established open a web browser and enter the address 169 254 2...

Page 68: ...odifying a Configuration File on page 66 and About the Exported Configuration File below Import configuration file Loads the Unity card configuration contained in a modified export file or a created file The import file is typically used to deploy common card settings See Importing a Configuration File on page 67 About the Exported Configuration File An exported configuration file contains all the...

Page 69: ...ext based values Numeric and enumerated values are not enclosed in double quotes Brackets indicate the folder that contains the settings User password and other secrets are hidden in the export file and the line is commented to prevent inadvertent import To import a new password or other secret un comment the line and enter the new password Because this is a text string it must be enclosed in doub...

Page 70: ...roSoft Windows devices The file is named with the prefix config_ followed by MAC address Year Month Day and Time This is included so that the file is uniquely identifiable See About the Exported Configuration File on page 64 for security and format details 1 On the Communications tab select Support Configuration Export Import 2 Click Enable and enter a user name and password Vertiv Liebert Intelli...

Page 71: ...ystem name or a network address by editing the configuration file to contain only those lines To import a configuration file 1 On the Communications tab select Support Configuration Export Import 2 Click Enable and enter a user name and password 3 Click Import and follow the instructions on the import dialog 6 7 4 Manually Restarting the Card 1 Locate the small hole on the front of the card that c...

Page 72: ...Vertiv Liebert IntelliSlot Unity Card Installer User Guide 68 This page intentionally left blank ...

Page 73: ...Vertiv Liebert IntelliSlot Unity Card Installer User Guide ...

Page 74: ...and logos referred to are trade names trademarks or registered trademarks of their respective owners While every precaution has been taken to ensure accuracyand completeness herein Vertiv Co assumes no responsibility and disclaims allliability for damages resulting from use of this information or for any errors or omissions Specifications are subject to change without notice SL 52645_REV11 590 130...

Reviews: