background image

vertilux.com

PROGRAMMING INSTRUCTIONS

MANUAL DE PROGRAMACIÓN

VTi

®

 CELTIC

TUBULAR MOTOR 

RF | AC WITH 

MECHANICAL LIMITS

MOTOR TUBULAR VTi

® 

CELTIC RF | AC

CON LÍMITES MECÁNICOS

SERIES Ø35 

Ø45 

I

 Ø55

vertilux.com

PROGRAMMING INSTRUCTIONS

MANUAL DE PROGRAMACIÓN

Summary of Contents for 6-700-CM-35R06

Page 1: ...INSTRUCTIONS MANUAL DE PROGRAMACI N VTi CELTIC TUBULAR MOTOR RF AC WITH MECHANICAL LIMITS MOTOR TUBULAR VTi CELTIC RF AC CON L MITES MEC NICOS SERIES 35 I 45 I 55 vertilux com PROGRAMMING INSTRUCTION...

Page 2: ...00 CN 45R20 6 700 CM 45R50 I 6 700 CN 45R50 6 700 CM 45M50 I 6 700 CN 45M50 6 700 CM 55M00 I 6 700 CN 55M00 ENGLISH Features Reliable and consistent mechanical limits Not affected by voltage variation...

Page 3: ...preconfigured during the fabrication of the shade and not during the final installation Warning VTi Celtic motors are weather resistant in a protected environment ex covered terrace but not waterproof...

Page 4: ...damage to the limit screws and void the warranty Pairing the motor with the remote control DO NOT SET LIMITS USING A DRILL ONLY USE THE PLASTIC HEXDRIVER THAT COMES WITH THE MOTOR TO SET THE LIMITS 1...

Page 5: ...has now changed its direction Setting or modifying limits depending on the type of installation MOTOR ON THE LEFT POSITION I LIMIT ADJUSMENT SCREW GREY SETS LOWER LIMIT POSITION II LIMIT ADJUSMENT SC...

Page 6: ...on on the remote control until the motor stops Check the current position of the upper limit and follow either procedure depending on your case If the current upper limit is above the desired limit fo...

Page 7: ...current position of the lower limit and follow either procedure depending on your case If the current lower limit is above the desired limit follow the procedure below depending on the position of th...

Page 8: ...trol using this procedure Changing to tilt or jog mode Tilt or jog mode initiates a short motor movement when pressing either up or down buttons The tilt or jog mode is convenient for Venetian Blinds...

Page 9: ...ted channel has been deleted Motors previously linked to this channel are not linked anymore 1 Select the desired channel using the channel selector button and press and hold the stop button for about...

Page 10: ...own on overheat protection Make sure there are no more than 5 motors per 15 A breaker or additional loads The drive and the crown are not well adapted to the tube The shade is not snug between the bra...

Page 11: ...6 700 CM 45R50 I 6 700 CN 45R50 6 700 CM 45M50 I 6 700 CN 45M50 6 700 CM 55M00 I 6 700 CN 55M00 ESPA OL 10 vertilux com Caracter sticas L mites mec nicos estables que no son afectados por fluctuacione...

Page 12: ...la fabricaci n de la cortina y no durante la instalaci n final El bottomrail no debe ser instalado hasta que los l mites del motor no hayan sido configurados Importante Los motores VTi Celtic de Verti...

Page 13: ...a que el motor realice un movimiento Compruebe que el motor se encuentra enlazado al control remoto No martille ni taladre el motor puede afectar su funcionamiento y anular la garant a El uso de un ta...

Page 14: ...RIOR RANURA DE AJUSTE I COLOR GRIS AJUSTA EL L MITE SUPERIOR RANURA DE AJUSTE II COLOR AMARILLO AJUSTA EL L MITE INFERIOR DERECHA IZQUIERDA MOTOR A LA DERECHA DERECHA IZQUIERDA Esta funci n es conveni...

Page 15: ...do y luego presione el bot n de subida de modo que pueda probar la posici n del nuevo l mite Verifique si su condici n actual es la descrita en el caso 1 o 2 y realice el procedimiento nuevamente seg...

Page 16: ...erior siga el procedimiento seg n sea su caso Si el l mite inferior actual se encuentra por encima del deseado siga el procedimiento seg n la ubicaci n del motor L mite actual L mite inferior deseado...

Page 17: ...funci n de giro de lamas est configurada el motor realiza peque os movimientos al presionar los botones de subida o bajada Esta funci n es conveniente para las cortinas venecianas persianas de madera...

Page 18: ...ha cometido un error durante la programaci n y se requiere borrar un solo canal Tambi n se aplica si se desea borrar un motor de un canal espec fico Desconecte de la corriente todos los motores excep...

Page 19: ...or levanta la cortina lentamente o se detiene antes de completar el ciclo El motor se ha detenido repentinamente durante su funcionamiento El motor ha alcanzado su m ximo n mero de vueltas Tenga en cu...

Page 20: ......

Reviews: