background image

FCC ID: K6630053X30

IC ID: 511B-30053X30

Alignment

4/7

Vertex Standard Co,. Ltd.

ˆ

 Use 

the 

H/L

 key to set transceiver to 

high power

 and set the channel to 

CH16

. With

the 

PTT

 switch pressed, adjust 

VR1001

 so that RF power is 25 W.

ˆ

 Use 

the 

H/L

 key to set transceiver to 

low power

 and set the channel to 

CH16

. With

the 

PTT

 switch pressed, adjust 

VR1002

 so that RF power is 0.8 W.

-- Confirmation --

ˆ

 Use 

the 

H/L

 key to set transceiver to 

high power

 and set the channel to 

EXP01

. With

the 

PTT

 switch pressed, confirm that RF power is between 23 W and 27 W.

ˆ

 Use 

the 

H/L

 key to set transceiver to 

low power

. With the 

PTT

 switch pressed,

confirm that RF power is between 0.5 W and 1.0 W.

ˆ

  As descried above, confirm RF power at 

EXP04

 and 

EXP05

. Set transceiver to 

high

power

 and confirm that RF power is between 23 W and 27 W. Set transceiver to 

low

power

 and confirm that RF power is between 0.5 W and 1.0 W.

Adjustment of PLL Frequency

Adjust the frequency in the transmit mode and local frequency in the receive mode.
-- Adjustment --

ˆ

  Setup the test equipment as shown below.

ˆ

  Set the channel to 

CH16

. With the 

PTT

 switch pressed, adjust 

TC1001

 so that RF

frequency is 156.80000 MHz ± 50 Hz.

Adjustment and Confirmation of Deviation

Adjust deviation in the transmit mode.
-- Adjustment --

ˆ

  Setup the test equipment as shown below.

ˆ

  Set the channel to 

CH16

.

ˆ

  Set the output of the audio generator (AG) to 1 KHz and 150 mV.

ˆ

 With 

the 

PTT

 switch pressed, adjust 

VR1003

 so that the maximum deviation is ±4.5

KHz.

ˆ

  Decrease the output level of AG by 20 dB (the output level of AG should be 1/10).

ˆ

 With 

the 

PTT

 switch pressed, adjust the output level of AG so that the deviation is ±3.0

KHz.

ˆ

  Increase the output level of AG by 20 dB (10 times of the output level of AG) which is

supposed to be Detective Modulation Level ±4.5 KHz).

ˆ

  Repeat steps 3 though 6 three times so that deviation is ±3.0 KHz and the maximum

deviation is ±4.4 KHz to ±4.6 KHz.

-- Confirmation --

ˆ

  Set the output of the AG to 1 KHz and 150 mV.

ˆ

  Set the channel to 

EXP01

, confirm that maximum deviation is between ±4.3 KHz and

Summary of Contents for GX1256S

Page 1: ...make complete performance checks to ensure compliance with factory specifications after replacing any faulty components Those who do undertake any of the following alignments are cautioned to proceed at their own risk Problems caused by unauthorized attempts at realignment are not covered by the warranty policy Also Standard Horizon a division of VERTEX STANDARD must reserve the right to change ci...

Page 2: ...etermine whether the same test equipment will be required If not remove the test equipment except dummy load and wattmeter if connected before proceeding Correct alignment requires that the ambient temperature be the same as that of the transceiver and test equipment and that this temperature be held constant between 20 C and 30 C 68 F and 86 F When the transceiver is brought into the shop from ho...

Page 3: ...transmission C Scan the channels between WX10 and EXP04 in the SCAN mode Starting Test Mode Confirm that PWR VOL switch is off and short the TEST points Turn on the PWR VOL switch while press and holding the DIST and DW keys Confirmation of VCO Confirmation Connect the DC voltmeter to the test point LOCK TP Use the UP DOWN key to set the channel to EXP04 confirm that voltage on the test point is o...

Page 4: ...cy Adjust the frequency in the transmit mode and local frequency in the receive mode Adjustment Setup the test equipment as shown below Set the channel to CH16 With the PTT switch pressed adjust TC1001 so that RF frequency is 156 80000 MHz 50 Hz Adjustment and Confirmation of Deviation Adjust deviation in the transmit mode Adjustment Setup the test equipment as shown below Set the channel to CH16 ...

Page 5: ...yzer to 159 00 MHz set SPAN to 20 00 MHz set RBW and VBW to 30 KHz and set SWP to 56 ms Adjust T1001 T1002 T1003 T1004 and T1005 until the wave form shown in below is obtained Note Adjust the output of the tracking generator so that RF AMP and spectrum analyzer will not saturate Figure shows the reference wave form The wave form varies with measuring instruments It is impotent to take the lowest p...

Page 6: ...ta Input NMEA format data output from GPS receiver to NMEA terminal A of transceiver and display it to the LCD of the transceiver NMEA format data output from GPS receiver is applied to NMEA terminal of transceiver s option connector and LCD of transceiver will show data Confirmation Setup the test equipment as shown below Press and hold the H L key confirm that the position data is displayed on t...

Page 7: ...I is displayed in the LCD of the test transceiver Confirm that the confirmation transceiver receives the response from the test transceiver and outputs beep Press the CALL SET key of the confirmation transceiver and turn off the beep Simultaneously confirm that TEST of test transceiver s MMSI is displayed in the LCD of the confirmation transceiver ...

Reviews: