background image

FCC ID: K6630053X30

IC ID: 511B-30053X30

Alignment

3/7

Vertex Standard Co,. Ltd.

(a) Expansion channels “EXP01 - EXP07” will be set as follows:

DISPLAY

RX Frequency

TX Frequency

SCAN Channel

EXP01

156.050 MHz

156.050 MHz

X

EXP02

157.425 MHz

157.425 MHz

X

EXP03

163.275 MHz

158.675 MHz

X

EXP04

155.050 MHz

155.050 MHz

O

EXP05

162.025 MHz

162.025 MHz

X

EXP06

163.575 MHz

158.975 MHz

X

EXP07

159.050 MHz

159.050 MHz

X

WX10

163.275 MHz

---

O

(B) In CH70, every time you are in transmit mode, (every time you press PTT), the

following test tone can be outputted:

1st transmission:

1300 Hz

2nd transmission: 2100 Hz
3rd transmission: No modulation
4th transmission: Synthetic tone of 1300 Hz and 2100 Hz
5th transmission: Return to 1st transmission

(C) Scan the channels between WX10 and EXP04 in the SCAN mode.

Starting Test Mode

Confirm that 

PWR/VOL

 switch is off, and short the TEST points. Turn on the 

PWR/VOL

switch while press and holding the 

DIST

 and 

DW

 keys.

Confirmation of VCO

-- Confirmation --

ˆ

  Connect the DC voltmeter to the test point (LOCK TP).

ˆ

 Use 

the 

UP/DOWN

 key to set the channel to 

EXP04

, confirm that voltage on the test

point is over 1.0 V in the receive and transmit mode.

ˆ

 Use 

the 

UP/DOWN

 key to set the channel to 

EXP05

, confirm that voltage on the test

point is below 5.0 V in the transmit mode.

ˆ

 Use 

the 

UP/DOWN

 key to set the channel to 

EXP06

, confirm that voltage on the test

point is below 5.0 V in the receive mode.

Adjustment and Confirmation of Transmit Power

Adjust power at high and low in the transmit mode, and confirm power in the specified
bandwidth.
-- Adjustment --

ˆ

  Connect the wattmeter and 50-ohm dummy load to the antenna jack.

Summary of Contents for GX1256S

Page 1: ...make complete performance checks to ensure compliance with factory specifications after replacing any faulty components Those who do undertake any of the following alignments are cautioned to proceed at their own risk Problems caused by unauthorized attempts at realignment are not covered by the warranty policy Also Standard Horizon a division of VERTEX STANDARD must reserve the right to change ci...

Page 2: ...etermine whether the same test equipment will be required If not remove the test equipment except dummy load and wattmeter if connected before proceeding Correct alignment requires that the ambient temperature be the same as that of the transceiver and test equipment and that this temperature be held constant between 20 C and 30 C 68 F and 86 F When the transceiver is brought into the shop from ho...

Page 3: ...transmission C Scan the channels between WX10 and EXP04 in the SCAN mode Starting Test Mode Confirm that PWR VOL switch is off and short the TEST points Turn on the PWR VOL switch while press and holding the DIST and DW keys Confirmation of VCO Confirmation Connect the DC voltmeter to the test point LOCK TP Use the UP DOWN key to set the channel to EXP04 confirm that voltage on the test point is o...

Page 4: ...cy Adjust the frequency in the transmit mode and local frequency in the receive mode Adjustment Setup the test equipment as shown below Set the channel to CH16 With the PTT switch pressed adjust TC1001 so that RF frequency is 156 80000 MHz 50 Hz Adjustment and Confirmation of Deviation Adjust deviation in the transmit mode Adjustment Setup the test equipment as shown below Set the channel to CH16 ...

Page 5: ...yzer to 159 00 MHz set SPAN to 20 00 MHz set RBW and VBW to 30 KHz and set SWP to 56 ms Adjust T1001 T1002 T1003 T1004 and T1005 until the wave form shown in below is obtained Note Adjust the output of the tracking generator so that RF AMP and spectrum analyzer will not saturate Figure shows the reference wave form The wave form varies with measuring instruments It is impotent to take the lowest p...

Page 6: ...ta Input NMEA format data output from GPS receiver to NMEA terminal A of transceiver and display it to the LCD of the transceiver NMEA format data output from GPS receiver is applied to NMEA terminal of transceiver s option connector and LCD of transceiver will show data Confirmation Setup the test equipment as shown below Press and hold the H L key confirm that the position data is displayed on t...

Page 7: ...I is displayed in the LCD of the test transceiver Confirm that the confirmation transceiver receives the response from the test transceiver and outputs beep Press the CALL SET key of the confirmation transceiver and turn off the beep Simultaneously confirm that TEST of test transceiver s MMSI is displayed in the LCD of the confirmation transceiver ...

Reviews: