(a) Expansion channels “EXP01 - EXP07” will be set as follows:
DISPLAY
RX Frequency
TX Frequency
SCAN Channel
EXP01
156.050 MHz
156.050 MHz
X
EXP02
157.425 MHz
157.425 MHz
X
EXP03
163.275 MHz
158.675 MHz
X
EXP04
155.050 MHz
155.050 MHz
O
EXP05
162.025 MHz
162.025 MHz
X
EXP06
163.575 MHz
158.975 MHz
X
EXP07
159.050 MHz
159.050 MHz
X
WX10
163.275 MHz
---
O
(B) In CH70, every time you are in transmit mode, (every time you press PTT), the
following test tone can be outputted:
1st transmission:
1300 Hz
2nd transmission: 2100 Hz
3rd transmission: No modulation
4th transmission: Synthetic tone of 1300 Hz and 2100 Hz
5th transmission: Return to 1st transmission
(C) Scan the channels between WX10 and EXP04 in the SCAN mode.
Starting Test Mode
Confirm that
PWR/VOL
switch is off, and short the TEST points. Turn on the
PWR/VOL
switch while press and holding the
DIST
and
DW
keys.
Confirmation of VCO
-- Confirmation --
Connect the DC voltmeter to the test point (LOCK TP).
Use
the
UP/DOWN
key to set the channel to
EXP04
, confirm that voltage on the test
point is over 1.0 V in the receive and transmit mode.
Use
the
UP/DOWN
key to set the channel to
EXP05
, confirm that voltage on the test
point is below 5.0 V in the transmit mode.
Use
the
UP/DOWN
key to set the channel to
EXP06
, confirm that voltage on the test
point is below 5.0 V in the receive mode.
Adjustment and Confirmation of Transmit Power
Adjust power at high and low in the transmit mode, and confirm power in the specified
bandwidth.
-- Adjustment --
Connect the wattmeter and 50-ohm dummy load to the antenna jack.