8
regulations and obligations of the Regulation of Interior Installations of Buildings (RITE
). Our company is not responsible for any damage related to the installation.
Following the safety precautions and recommendations described above, the pellet
stove or boiler can be connected to the radiators without using too many elbows with
approved 1" - 3/4" installation pipes. In this way, the hot water will circulate more easily
and the temperature in the radiators will be felt in a short time. The installation of the
main pipes to the pellet stove must be securely connected to the radiators using the
required fittings. Once the connection is made, the system will be filled with water by
the authorized person. After installation, the tightness of the installation, radiators and
valves must be checked and the air in the installation must be emptied. All this must
be done by authorized personnel.
*Depending on the climatic conditions of the region, it is recommended to use 1/3
portion of antifreeze against corrosion and freezing.
The pellet stove is a fully automatic product. Parts such as expansion tank, circulation
pump, thermostat, safety valve, and sensor are securely attached to the product.
It is a convenient product that provides fuel ignition with resistance, helical and reducer
group, fuel loading, chimney traction and blowing with fans.
4.3.1 ELECTRICITY
Electricity must be 230V / 50 Hz 10A. Our company is not responsible for any damage
that may occur in the event of any voltage drop or surge. We recommend taking the
necessary measures since it does not include the guarantee.