2-9
39026-03 02/17
VERSALIFT VST-8000/8500/9000/9500-I
RESPONSIBILITIES / SAFETY
Area 1, Boom Tip Area
– The boom tip area does
not provide insulation. This area includes everything
past the insulated section decal* on the upper boom.
This includes the upper end of the boom, platform
support, platform(s), controls, and the jib/winch/rope
(when so equipped).
All components at the boom tip area must be
considered to be conductive and electrically
connected, even with an insulated liner in place.
Any contact with a ground and a phase or between
two phase conductors will create a hazard of serious
personal injury or death. Contact between an
energized conductor and any part of the boom tip
will energize the entire boom tip.
When working near an energized conductor, ground
conductor, or other grounded objects, the operator
must use the proper safety equipment (such as
rubber gloves, covers, hot sticks, etc.), maintain
safe approach distances, and follow company work
practices.
Area 2, Upper Boom Insulation Section
– This
section provides insulation** between the boom
tip area and earth ground when clean and properly
maintained. On some confi gurations, it is necessary
to extend the boom until the insulated section decal
is visible.
Area 3, Intermediate Structure –
This section
does not provide insulation. This area includes
the lower steel portion of the upper boom, knuckle,
and the steel upper portion of the lower boom and
compensation link (when applicable).
Area 4, Lower Boom Insulating Section –
(When
so equipped) This section provides insulation**
between the intermediate structure (Area 3) and the
vehicle when clean and properly maintained.
Area 5, Lower Structure
– This area does not
provide insulation. This area includes the steel lower
portion of the lower boom and compensation link
(when applicable), turret, lower controls, pedestal,
and the vehicle.
* On VST and T-Series models not supplied with an
upper insulated section decal, the insulated section
begins 11 inches below the center of the platform
pivot.
** Insulation properties are defi ned by ANSI A92.2
WHAT IS INSULATED AND WHAT IS NOT INSULATED
ARTICULATED/TELESCOPIC AND ARTICULATED MODELS
Summary of Contents for VST-8000-I
Page 2: ......
Page 4: ......
Page 6: ......
Page 11: ...2 3 39026 03 02 17 VERSALIFT VST 8000 8500 9000 9500 I RESPONSIBILITIES SAFETY ...
Page 12: ...2 4 39026 03 02 17 VERSALIFT VST 8000 8500 9000 9500 I RESPONSIBILITIES SAFETY ...
Page 13: ...2 5 39026 03 02 17 VERSALIFT VST 8000 8500 9000 9500 I RESPONSIBILITIES SAFETY ...
Page 24: ...3 6 39026 03 02 17 VERSALIFT VST 8000 8500 9000 9500 I SPECIFICATIONS ...
Page 26: ...3 8 39026 03 02 17 VERSALIFT VST 8000 8500 9000 9500 I SPECIFICATIONS ...
Page 28: ...3 10 39026 03 02 17 VERSALIFT VST 8000 8500 9000 9500 I SPECIFICATIONS ...
Page 30: ...3 12 39026 03 02 17 VERSALIFT VST 8000 8500 9000 9500 I SPECIFICATIONS ...
Page 31: ...3 13 39026 03 02 17 VERSALIFT VST 8000 8500 9000 9500 I SPECIFICATIONS ...
Page 32: ...3 14 39026 03 02 17 VERSALIFT VST 8000 8500 9000 9500 I SPECIFICATIONS ...
Page 33: ...3 15 39026 03 02 17 VERSALIFT VST 8000 8500 9000 9500 I SPECIFICATIONS ...
Page 34: ...3 16 39026 03 02 17 VERSALIFT VST 8000 8500 9000 9500 I SPECIFICATIONS ...
Page 36: ...3 18 39026 03 02 17 VERSALIFT VST 8000 8500 9000 9500 I SPECIFICATIONS ...
Page 37: ...3 19 39026 03 02 17 VERSALIFT VST 8000 8500 9000 9500 I SPECIFICATIONS ...
Page 38: ...3 20 39026 03 02 17 VERSALIFT VST 8000 8500 9000 9500 I SPECIFICATIONS ...
Page 39: ...3 21 39026 03 02 17 VERSALIFT VST 8000 8500 9000 9500 I SPECIFICATIONS ...
Page 40: ......
Page 54: ......
Page 62: ...6 4 39026 03 02 17 VERSALIFT VST 8000 8500 9000 9500 I DAILY VISUAL INSPECTION ...
Page 63: ...6 5 39026 03 02 17 VERSALIFT VST 8000 8500 9000 9500 I DAILY VISUAL INSPECTION ...
Page 64: ...6 6 39026 03 02 17 VERSALIFT VST 8000 8500 9000 9500 I DAILY VISUAL INSPECTION ...