Vernacare Compact Plus Technical Manual-
Revision 2-Issued by N.Shields 14.2.2020
Page | 34
8.
Sensor Arrangement
10
8
6
4
2
9
7
5
3
KQ6004
IFM Sensor
KQ6004-E12154
IFM Sensor with mount
KQ6004-E12154
IFM Sensor with mount
LOW DEODORISER
LOW WATER
HOPPER FULL
FOOT SENSOR
P-SWITCH (LID SEAL)
P-SWITCH (DIAPHRAGM)
PRESSURE TRANSDUCER
LID OPEN
LID CLOSED
LID SAFETY
1
UGR***
IFM Ultrasonic Sensor
PV7004
IFM Pressure Switch
PV7004
IFM Pressure Switch
Drain Pressure Switch 9210212
MK5122
IFM Magnetic Sensor
MK5122
IFM Magnetic Sensor
S870W1D1T
Limit Safety Switch
IFM SPLITTER BOX
10 x M8
EBC0136
EVC256 M12(F) to M8(M) Jumper Cable
EVC256 M12(F) to M8(M) Jumper Cable
EVC256 M12(F) to M8(M) Jumper Cable
BLANK
EVC271 M8(F) to M8(M) Jumper Cable
EVC271 M8(F) to M8(M) Jumper Cable
EVC271 M8(F) to M8(M) Jumper Cable
M8 1m Long Cable on Sensor
M8 1m Long Cable on Sensor
M8 Cable fitted to p-switch unit
0
8
6
4
2
9
7
5
3
1
Summary of Contents for COMPACT+