25

Vermont Castings Vigilant

2000898

Vigilant Coal II 

Model 2310 (continued)

 

  Item Description 

Part Number

 

  Item Description 

Part Number

  13. 

Triangle Firebrick 

1600906

  14. 

Right Inner Side 

1305002

  15. 

Tie Rod (1) 

1601629 

 

 

 

Tie Rod Set (4) 

5007497

  16. 

Rear Grate Support 

1305011

  17. 

High Grate Bar 

1305040

  18. 

Low Grate Bar 

1305039

  19. 

Front Grate Support 

1305009

  20. 

Left Inner Side 

1305001

  21. 

Primary Air Tube 

1305015

  22. 

Front 

1304273

 

 

Front with Doors Assembly 

5000945

  23. 

Right Door 

1304216

  24. 

Left Door 

1304224 

 

 

 

Door Pin (Hinge Pin) 3/16 x 1

¹⁄₈

 - NJ 

1600546

  25. 

Glass Panel 

1401119

  26. 

3/16” Fiberglass Gasket and Black 

1203556

  27. 

Long Glass Clip Retainer - s/s 

1601392

  28. 

Short Glass Clip Retainer - s/s 

1601391

  29. 

5/16” Fiberglass Gasket 

1203588

  30. 

Latch Pawl Assembly 

5004024

  31. 

Ashpan Cover w/ Handle 

1601027

  32. 

Shaker Handle 

1600903

  33. 

Ashpan 

1400927

  34. 

Ashdoor 

1305045

  35. 

Front Door Handle Assembly 

5004237

  36. 

Ashpan Bracket 

1601039

  37. 

Ashdoor Hinge 

1305046

  38. 

Ashdrop 

1305044

  39. 

Bottom 

1305043

  40. 

10” Leg 

1305048

  41. 

Left End 

1304269

  42. 

Shaker Handle Support 

1305049

  43. 

Ashdoor Hinge Pin 

1201835

  44. 

Ceramic Handle Assembly 

0004342

  45. 

Damper Handle Assembly 

5004265

  46. 

Lower Fireback 

1305025

  47. 

Back 

1304278

  48. 

6” Round Flue Collar 

1305050

  49. 

Shaker Rod (10

¹⁄₂

”) 

1600904 

  50. 

Air Control 

1300671

  51. 

5/16” Adhesive-backed Gasket 

1203591

  52. 

5/16” Armaseal Gasket 

1203668

  53. 

Thermostat Assembly 

5005483

  54. 

Thermostat Cover 

1601487

  55. 

Thermostat Flap Assembly 

N/A 

 

 

 

Substitute: 

5005410

  56. 

Thermostat Pivot Pin 

1601555

  57. 

Ashdoor Handle with Shaft 

5004244

  58. 

Cleanout Cover 

1602202

  59. 

C-Clip 

1600553

  61. 

Slicer/Poker Assembly 

5005708

  62. 

Ashpan Cover Handle 

1301254

 

 

Airplate 

1600908

 

 

Allen Wrench, 1/8” 

1205116

 

 

Allen Wrench, 5/32” 

1205147

 

 

Door Handle Holder 

1600600

Summary of Contents for Vigilant II

Page 1: ...se SAFETY NOTICE IF THIS APPLIANCE IS NOT PROPERLY INSTALLED OPERATED AND MAINTAINED A HOUSE FIRE MAY RESULT TO REDUCE THE RISK OF FIRE FOLLOW THE INSTALLATION INSTRUCTIONS FAILURE TO FOLLOW INSTRUCTI...

Page 2: ...ur Authorized Vermont Castings Dealer anytime you have a particular question about your stove or its performance Be assured that your cast iron Vermont Castings stove or replace has been made with the...

Page 3: ...ption obtained under laboratory conditions and on average ef ciencies These values are based on operation in building code conforming homes under typical winter climate condi tions in New England If y...

Page 4: ...eight due largely to a difference in temperature between the gases inside the chimney and gases out side the chimney Because gas expands when heated warm gases inside the chimney weigh less than cool...

Page 5: ...necessary for this type of installation The chimney should extend at least 3 feet above the highest point where it passes through a roof and at least 2 feet higher than any portion of a building with...

Page 6: ...VE OR INSERT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE Chimney Size When out tted with the standard 6 150 mm ue col lar The Vigilant II Coal Stove is designed to perform well when vented through ues...

Page 7: ...ove will be in either a parallel or a corner instal lation not both Use only the part of the chart that ap plies to your installation Note Side clearances do not apply to corner installations Measure...

Page 8: ...mum clearance parallel installation rear heat shield For rear exiting stoves both rear and side clearances are determined by the heat from the stove provided that the connector does not pass near a co...

Page 9: ...ed to change an unprotected wall to a protected wall allow ing the clearances given in the right half of the Clear ance Chart Wall shields should be constructed of 24 gauge or heavier sheetmetal 1 2 n...

Page 10: ...mm Clearance to Combustibles in Front of Stove 1 A ceiling heat shield 24 610 mm in diameter and suspended 1 25 mm from the ceiling must surround the chimney con nector in installations in which the...

Page 11: ...mm D 16 406 mm E 12 305 mm F 2 51 mm to either side of connector Fig 12 Minimum oor protection requirements ST689 oor protector must meet the same requirements as for standard legs Floor Protection f...

Page 12: ...market which have been tested and listed speci cally for use as wall pass throughs Use only these tested and listed accessories for wall pass throughs The National Fire Protection Association NFPA has...

Page 13: ...cessories The Removable Handle The removable handle is inserted into the front door stub or the damper handle stub when you want to open or close the doors or change the position of the damp er The ha...

Page 14: ...Coal Stove Freestanding If the chimney connector must pass through a combustible wall to reach the chimney follow the recommendations in the Wall Pass Through sec tion ST243 thinble connection 12 13...

Page 15: ...e Watch these points If there is a combustible mantel or trim check the stove and chimney connector clearances in the Clearance Chart Use the necessary combination of mantel trim and connector heat sh...

Page 16: ...nformation about the ash content of the coal he sells The Vigilant II Coal Stove is designed to burn anthracite hard coal or bituminous coal soft coal Do not burn other fuels As shipped from the facto...

Page 17: ...is between 400 and 700 F although temperatures slightly outside of this range may be expected However if tempera tures go above 700 F for extended periods decrease the air supply move the thermostat...

Page 18: ...smaller and draft problems can result Avoid draft problems when the outside temperature is 35 F or higher by operating your stove with the damper open to keep ue temperatures high If draft problems o...

Page 19: ...striker screw one turn and re tight ening the small locking nut Keep making adjustments slowly until the setting is right The handle should resist slightly as it is turned to the closed position and t...

Page 20: ...e plate and then slide it toward the front of the stove so the end with the shorter offset will be behind the iron The cover in the lower reback will be inserted into the opening and pushed to the lef...

Page 21: ...side up on a level work sur face 2 Remove the two retainer clips Carefully remove the old glass 3 Examine the gasketing Worn gasketing should be replaced Remove the old gasketing Cut new gasket ing to...

Page 22: ...y two weeks during the heating season to determine if a soot buildup has occurred If soot has accumulated it should be removed to reduce the risk of a chimney re Fly ash carried from the fuel bed by d...

Page 23: ...if any appear to be corroded Is the door handle adjusted so the doors close tight ly Instructions for adjusting the handle are given in the Maintenance Section Draft Problems If the draft in the chim...

Page 24: ...m Description Part Number Item Description Part Number CFM Corporation reserves the right to make changes in design materials speci cations prices and discontinue colors and products at any time witho...

Page 25: ...n Cover w Handle 1601027 32 Shaker Handle 1600903 33 Ashpan 1400927 34 Ashdoor 1305045 35 Front Door Handle Assembly 5004237 36 Ashpan Bracket 1601039 37 Ashdoor Hinge 1305046 38 Ashdrop 1305044 39 Bo...

Page 26: ...26 Vermont Castings Vigilant 2000898...

Page 27: ...s 1 This warranty is transferable however proof of original purchase is required 2 CFM Corporation offers no warranty on chipping of enamel surfaces Inspect your Vigilant II Coal Stove prior to accept...

Page 28: ...2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation...

Reviews: