background image

12

Vermont Castings VCBVMN/MP  & VCPVMN/MP Room Heaters

11

13

14

15

10a,b

9

7

8a,b

5

2

3

1

4

16

16

17

19a

21

18

20

22

23

24

19b

12a,b

6a,b

The Vermont Castings Majestic Products Company reserves the right to make changes in design, materials, specifications, prices and discontinue
colors and products at any time, without notice.

3769

VCBVMN/MP Unvented Room Heater

Item / Model Number

VCBV10MN/MP

VCBV20MN/MP

VCBV30MN/MP

1.

Guard Assembly

RBW33XX0

RBW30XX0

RBW26XX0

2.

Glass Panel

RBC02XC0

RBC02XB0

RBC02XA0

3.

Holder Glass

RBP63PC0

RBP63PB0

RBP63XPA0

4.

Reflector

RBP71PX0

RBP70PX0

RBW23XX0

5.

Cover Heat - Upper

--

RBP61XB0

RBP61XA0

6a.

Pressure Regulator (Daemyeong Korea) - Natural

DR40M2PN

DR40M2KN

DR40M3KN

6b.

Pressure Regulator (Daemyeong Korea) - LP

DR40M2PL

DR40M2KL

DR40M3KL

7.

Nozzle Holder

RBM06XX0

RBM06XX0

RBM06XX0

8a.

ODS Pilot Assembly (Daemyeong Korea) - Natural

DS98N02

DS98N02

DS98N02

8b.

ODS Pilot Assembly (Daemyeong Korea) - LP

DS98PL02

DS98PL02

DS98PL02

9.

Fix Nut - Nozzle Holder

RBM08XX0

RBM08XX0

RBM08XX0

10a.

Main Nozzle - Natural

RBM07XE

RBM07XA

RBM07XC

10b.

Main Nozzle - LP

RBM07F0

RBM07B0

RBM07E0

11.

Bracket - Valve

RBP59XX0

RBP59XX0

RBP59XX0

12a.

Gas Control (Daemyeong Korea) - Natural

DMV101PA

DMV100PA

DMV100PC

12b.

Gas Control (Daemyeong Korea) - LP

DMV101PB

DMV100PB

DMV100PD

13.

Tubing Outlet Assembly

RBT28XX0

RBT22XX0

RBT16XX0

Summary of Contents for VCBV10

Page 1: ...ighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency...

Page 2: ...lace High traffic area Drafty areas This heater needs fresh outside air for ventilation to run properly This heater has an oxygen depletion sensor ODS pilot light safety system The ODS shuts down the...

Page 3: ...for each 1 000 feet above sea level DO NOT USE THIS HEATER AT AN ELEVATION ABOVE 4 500 FEET Local Codes VCBV30 VCBV20 VCBV10 VCPV30 VCPV18 VCPV10 VCPV06 Certified to ANSI Z21 11 2b 2002 Unvented Heat...

Page 4: ...directly with the space in which the appliances are installed through openings not furnished with doors are consid ered a part of the unconfined space Confined space A confined space whose volume is...

Page 5: ...ed promptly inform dealer distributor 4 Select a location for the heater that will provide maximum exposure of the radiant surface to the room but will not be subjected to accidental contact 5 Adequat...

Page 6: ...ge enough diameter to allow proper gas volume to heater If pipe is too small undue pressure loss will occur CAUTION Use pipe joint sealant that is resistant to liquefied petroleum gases Install sedime...

Page 7: ...upply piping system by closing the individual manual shut off valve Fig 7 during any pressure testing of the gas supply system at test pressures equal to or less than 1 2 psi Open Closed Manual Shut O...

Page 8: ...d turn counter clockwise to PILOT IGN and depress for five 5 seconds This will allow air to bleed from the gas system 6 Release control knob pressure and turn clockwise to OFF 7 Depress control knob w...

Page 9: ...your heater could produce increased levels of carbon monoxide If burner flame pattern shows yellow tipping follow instructions in the Troubleshooting section on page 10 NOTE Do not mistake orange fla...

Page 10: ...ontrol knob set between locked positions 1 Residues from manufacturing processes 1 Air passageways blocked 2 Air in gas line What To Do 1 Replace ignitor electrode 2 Replace electrode 3 Free ignitor c...

Page 11: ...rson Depending on the surround ings the room heater may require frequent cleaning due to excessive lint or debris Before cleaning ensure the gas supply is off and the gas control knob is in the OFF po...

Page 12: ...RBP71PX0 RBP70PX0 RBW23XX0 5 Cover Heat Upper RBP61XB0 RBP61XA0 6a Pressure Regulator Daemyeong Korea Natural DR40M2PN DR40M2KN DR40M3KN 6b Pressure Regulator Daemyeong Korea LP DR40M2PL DR40M2KL DR40...

Page 13: ...RBW22XA0 18 Burner Assembly RBW13XX0 RBW09XX0 RBW08XX0 19a Burner Support Left RBP06XA RBP06XA RBP06XA 19b Burner Support Right RBP06XB0 RBP06B0 RBP06B0 20 Frame Body Assembly RBW31PB0 RBW31PB0 RBW20P...

Page 14: ...P66PA0 RBP57PA0 7 Burner Body Assembly 2RH0006 RCW13XX0 RCW12XX0 RCW11XX0 8 Ceramic Plate 3D0310 RCC03XX0 RCC01XA0 RCC01XA0 9 Frame Body Assembly RBW32PB0 RBW32PB0 RBW27PB0 RBW20PB0 10 Knob Valve RB10...

Page 15: ...ld RBP84 RBP84 RBP101 RBP104 Accessories Contact Vermont Castings Majestic Products with questions concerning prices and policies covering replacement parts Parts may be ordered through you Vermont Ca...

Page 16: ...use of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diag nostic cost labor tra...