Install Log Set:
Before beginning log installation, remove stove front and
glass frame. Refer to Figures 42 and 43.
Note: Remove the safety barrier before you remove the
glass frame. To remove the barrier, simply lift up and pull
out until the tabs are clear of their corresponding slots
on the firebox. Then proceed to remove the glass frame
by following the steps below.
ST139
Radiance
remove front
4/20/01 djt
Figure 42
- Remove the safety barrier and stove front.
ST141
pull glass latch
10/99
Figure 43
- Release the latches to remove the glass frame.
ST358
DW
Decorative
pipe around b-vent
5/15/03 djt
Decorative
7” Pipe
4” B-vent
Pipe
Draft Hood
Adapter
HHT Direct Vent
System may be used
from Draft Hood up
to the ceiling
Figure 40
- Decorative 7” pipe may be fitted around the B-vent
pipe.
The stove, when installed as a Natural vent heater, includes
a vent safety switch. Operating the stove when it is not
connected to a properly installed and maintained venting
system, or tampering with or disconnecting the vent safety
switch, can result in carbon monoxide (CO) poisoning and
possible death.
For U.S. installations:
The venting system must conform
with local codes and/or the current National Fuel Gas Code,
ANSI Z22.1.
For Canadian installations:
The venting system must
conform to the current CSA B149.1 installation code.
Apply a bead of sealant around bottom end of inner starter
pipe (found in bag with logset) and attach to stove. Apply a
bead of sealant around top of inner starter pipe and install
the FSDHAGSLP Draft Hood according to Draft Hood
instructions. (Figure 41)
Attach the first section of venting to the draft hood.
Depending on the length of the individual venting sections
and the lengths of the decorative pipe (if installed), you may
need to slip the decorative pipe over the venting sections
before attaching upper sections to lower ones. The sections
of decorative pipe should be oriented with their seams (if
any) toward the wall; sections usually do not need to be
fastened at each joint, other than slip sections. If the layout
includes a slip section, this should be the last section of
pipe visible in the room, at the ceiling. Complete the venting
according to the vent maker’s instructions.
ST767
DW
attach draft hood
5/15/03 djt
CEMENT
Figure 41
- Install draft hood adapter.